Schneider Electric Pelco Sarix Professional up to 3.29 SSH Service /login/bin/set_param improper authentication
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
6.8 | $0-$5k | 0.00 |
A vulnerability was found in Schneider Electric Pelco Sarix Professional up to 3.29. It has been classified as critical. This affects some unknown functionality of the file /login/bin/set_param of the component SSH Service. The manipulation with an unknown input leads to a improper authentication vulnerability. CWE is classifying the issue as CWE-287. When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
The bug was discovered 03/01/2018. The weakness was presented 03/09/2018 (Website). The advisory is shared at schneider-electric.com. This vulnerability is uniquely identified as CVE-2018-7236 since 02/19/2018. It is possible to initiate the attack remotely. No form of authentication is needed for exploitation. It demands that the victim is doing some kind of user interaction. Technical details are known, but no exploit is available.
The vulnerability was handled as a non-public zero-day exploit for at least 8 days. During that time the estimated underground price was around $0-$5k.
Upgrading to version 3.29.67 eliminates this vulnerability.
See 114325, 114326, 114334 and 114335 for similar entries.
Product
Type
Vendor
Name
Version
- 3.0
- 3.1
- 3.2
- 3.3
- 3.4
- 3.5
- 3.6
- 3.7
- 3.8
- 3.9
- 3.10
- 3.11
- 3.12
- 3.13
- 3.14
- 3.15
- 3.16
- 3.17
- 3.18
- 3.19
- 3.20
- 3.21
- 3.22
- 3.23
- 3.24
- 3.25
- 3.26
- 3.27
- 3.28
- 3.29
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 7.2VulDB Meta Temp Score: 7.0
VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 8.1
NVD Vector: 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Improper authenticationCWE: CWE-287
CAPEC: 🔍
ATT&CK: 🔍
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Upgrade: Pelco Sarix Professional 3.29.67
Timeline
02/19/2018 🔍03/01/2018 🔍
03/09/2018 🔍
03/09/2018 🔍
03/10/2018 🔍
01/12/2020 🔍
Sources
Vendor: schneider-electric.comAdvisory: schneider-electric.com
Status: Not defined
Confirmation: 🔍
CVE: CVE-2018-7236 (🔍)
See also: 🔍
Entry
Created: 03/10/2018 22:56Updated: 01/12/2020 09:46
Changes: 03/10/2018 22:56 (61), 01/12/2020 09:46 (2)
Complete: 🔍
No comments yet. Languages: en.
Please log in to comment.