A vulnerability was found in Schneider Electric Modicon M580, Modicon M340, Modicon Premium and Modicon Quantum (SCADA Software) (version now known). It has been rated as problematic. Affected by this issue is some unknown processing of the component Modbus. The manipulation with an unknown input leads to a exceptional condition vulnerability. Using CWE to declare the problem leads to CWE-755. The product does not handle or incorrectly handles an exceptional condition. Impacted is availability. CVE summarizes:
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.
The weakness was presented 09/17/2019 (Website). The advisory is available at schneider-electric.com. This vulnerability is handled as CVE-2019-6828 since 01/25/2019. The exploitation is known to be easy. The attack may be launched remotely. No form of authentication is required for exploitation. The technical details are unknown and an exploit is not available.
Upgrading eliminates this vulnerability.
See 141933, 141939 and 141940 for similar entries.
Product
Type
Vendor
Name
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 6.4VulDB Meta Temp Score: 6.3
VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 7.5
NVD Vector: 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Exceptional conditionCWE: CWE-755
ATT&CK: Unknown
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Timeline
01/25/2019 🔍09/17/2019 🔍
09/18/2019 🔍
08/28/2020 🔍
Sources
Vendor: schneider-electric.comAdvisory: schneider-electric.com
Status: Not defined
Confirmation: 🔍
CVE: CVE-2019-6828 (🔍)
See also: 🔍
Entry
Created: 09/18/2019 11:25Updated: 08/28/2020 22:08
Changes: 09/18/2019 11:25 (56), 08/28/2020 22:08 (1)
Complete: 🔍
No comments yet. Languages: en.
Please log in to comment.