Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.1$0-$5k0.00

A vulnerability was found in Schneider Electric Modicon M580, Modicon M340, Modicon Premium and Modicon Quantum (SCADA Software) (version now known). It has been rated as problematic. Affected by this issue is some unknown processing of the component Modbus. The manipulation with an unknown input leads to a exceptional condition vulnerability. Using CWE to declare the problem leads to CWE-755. The product does not handle or incorrectly handles an exceptional condition. Impacted is availability. CVE summarizes:

A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.

The weakness was presented 09/17/2019 (Website). The advisory is available at schneider-electric.com. This vulnerability is handled as CVE-2019-6828 since 01/25/2019. The exploitation is known to be easy. The attack may be launched remotely. No form of authentication is required for exploitation. The technical details are unknown and an exploit is not available.

Upgrading eliminates this vulnerability.

See 141933, 141939 and 141940 for similar entries.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.4
VulDB Meta Temp Score: 6.3

VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Exceptional condition
CWE: CWE-755
ATT&CK: Unknown

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/25/2019 🔍
09/17/2019 +235 days 🔍
09/18/2019 +1 days 🔍
08/28/2020 +345 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: schneider-electric.com
Status: Not defined
Confirmation: 🔍

CVE: CVE-2019-6828 (🔍)
See also: 🔍

Entryinfo

Created: 09/18/2019 11:25
Updated: 08/28/2020 22:08
Changes: 09/18/2019 11:25 (56), 08/28/2020 22:08 (1)