Siemens SIMATIC/SINAMICS UDP Packet resource consumption

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.7$0-$5k0.00

A vulnerability, which was classified as problematic, was found in Siemens SIMATIC and SINAMICS (SCADA Software) (the affected version unknown). Affected is an unknown part. The manipulation as part of a UDP Packet leads to a resource consumption vulnerability. CWE is classifying the issue as CWE-400. The product does not properly control the allocation and maintenance of a limited resource, thereby enabling an actor to influence the amount of resources consumed, eventually leading to the exhaustion of available resources. This is going to have an impact on availability. CVE summarizes:

A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.2.3), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. F) (All versions), SIMATIC S7-1500 CPU family (incl. F) (All versions < V2.0), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400 V6 (incl F) and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 V8 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions), SINAMICS G150 (Control Unit) (All versions), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S150 (Control Unit) (All versions), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

The weakness was presented 10/10/2019 (Website). The advisory is shared for download at cert-portal.siemens.com. This vulnerability is traded as CVE-2019-10936 since 04/08/2019. It is possible to launch the attack remotely. The exploitation doesn't require any form of authentication. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1499.

Upgrading eliminates this vulnerability.

See 143327 for similar entry.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.8
VulDB Meta Temp Score: 6.7

VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.5
NVD Vector: 🔍

CNA Base Score: 7.5
CNA Vector (Siemens AG): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Resource consumption
CWE: CWE-400 / CWE-404
ATT&CK: T1499

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

04/08/2019 🔍
10/10/2019 +185 days 🔍
10/11/2019 +1 days 🔍
01/07/2024 +1549 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-473245
Status: Not defined

CVE: CVE-2019-10936 (🔍)
See also: 🔍

Entryinfo

Created: 10/11/2019 09:29
Updated: 01/07/2024 16:14
Changes: 10/11/2019 09:29 (38), 10/01/2020 09:43 (18), 01/07/2024 16:06 (4), 01/07/2024 16:14 (12)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!