Schneider Electric Modicon M580 Modbus TCP unusual condition

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.2$0-$5k0.00

A vulnerability was found in Schneider Electric Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium (SCADA Software) (the affected version is unknown). It has been rated as problematic. This issue affects an unknown code of the component Modbus TCP. The manipulation with an unknown input leads to a unusual condition vulnerability. Using CWE to declare the problem leads to CWE-754. The product does not check or incorrectly checks for unusual or exceptional conditions that are not expected to occur frequently during day to day operation of the product. Impacted is availability. The summary by CVE is:

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.

The weakness was published 01/06/2020 (Website). It is possible to read the advisory at se.com. The identification of this vulnerability is CVE-2019-6857 since 01/25/2019. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. The technical details are unknown and an exploit is not publicly available.

Addressing this vulnerability is possible by firewalling .

Similar entries are available at 148305 and 148354.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.4
VulDB Meta Temp Score: 6.3

VulDB Base Score: 5.3
VulDB Temp Score: 5.2
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Unusual condition
CWE: CWE-754
ATT&CK: Unknown

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Firewall
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/25/2019 🔍
01/06/2020 +346 days 🔍
01/07/2020 +1 days 🔍
01/07/2020 +0 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: se.com
Status: Not defined

CVE: CVE-2019-6857 (🔍)
See also: 🔍

Entryinfo

Created: 01/07/2020 11:10
Updated: 01/07/2020 11:15
Changes: 01/07/2020 11:10 (38), 01/07/2020 11:15 (18)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Might our Artificial Intelligence support you?

Check our Alexa App!