Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.0$0-$5k0.00

A vulnerability has been found in Schneider Electric PowerLogic ION7400, PowerLogic ION7650, PowerLogic ION83xx, PowerLogic ION84xx, PowerLogic ION85xx, PowerLogic ION8600, PowerLogic ION8650, PowerLogic ION8800, PowerLogic ION9000 and PowerLogic PM800 (SCADA Software) and classified as problematic. Affected by this vulnerability is an unknown code block of the component HTTP Web Interface. The manipulation with an unknown input leads to a cross-site request forgery vulnerability. The CWE definition for the vulnerability is CWE-352. The web application does not, or can not, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. As an impact it is known to affect integrity.

The weakness was presented 02/20/2021 as SEVD-2021-040-01. It is possible to read the advisory at se.com. This vulnerability is known as CVE-2021-22701. It demands that the victim is doing some kind of user interaction. The technical details are unknown and an exploit is not publicly available.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 4.0
VulDB Meta Temp Score: 4.0

VulDB Base Score: 3.5
VulDB Temp Score: 3.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 4.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Cross-site request forgery
CWE: CWE-352 / CWE-862 / CWE-863
ATT&CK: Unknown

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/06/2021 🔍
02/20/2021 +45 days 🔍
02/20/2021 +0 days 🔍
03/03/2021 +11 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2021-040-01
Status: Not defined

CVE: CVE-2021-22701 (🔍)

Entryinfo

Created: 02/20/2021 21:29
Updated: 03/03/2021 21:14
Changes: 02/20/2021 21:29 (37), 03/03/2021 21:10 (2), 03/03/2021 21:14 (18)