Schneider Electric C-Bus Toolkit up to 1.15.8 missing authentication
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
7.0 | $0-$5k | 0.00 |
A vulnerability, which was classified as critical, was found in Schneider Electric C-Bus Toolkit up to 1.15.8 (SCADA Software). Affected is some unknown functionality. The manipulation with an unknown input leads to a missing authentication vulnerability. CWE is classifying the issue as CWE-306. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. This is going to have an impact on confidentiality, integrity, and availability.
The weakness was presented 07/22/2021 as SEVD-2021-194-04. The advisory is shared for download at download.schneider-electric.com. This vulnerability is traded as CVE-2021-22784. There are neither technical details nor an exploit publicly available.
Applying a patch is able to eliminate this problem.
Product
Type
Vendor
Name
Version
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 7.3VulDB Meta Temp Score: 7.0
VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Missing authenticationCWE: CWE-306 / CWE-287
ATT&CK: Unknown
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔍
Timeline
01/06/2021 🔍07/22/2021 🔍
07/22/2021 🔍
07/26/2021 🔍
Sources
Vendor: schneider-electric.comAdvisory: SEVD-2021-194-04
Status: Confirmed
CVE: CVE-2021-22784 (🔍)
Entry
Created: 07/22/2021 05:44Updated: 07/26/2021 09:23
Changes: 07/22/2021 05:44 (38), 07/26/2021 09:23 (2)
Complete: 🔍
No comments yet. Languages: en.
Please log in to comment.