Powertek PDU prior 3.30.30 HTTP API /cgi/get_param.cgi user.token permission

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.1$0-$5k0.00

A vulnerability classified as critical has been found in Powertek PDU. Affected is an unknown functionality of the file /cgi/get_param.cgi of the component HTTP API. The manipulation of the argument user.token with an unknown input leads to a permission vulnerability. CWE is classifying the issue as CWE-275. This is going to have an impact on confidentiality, integrity, and availability. CVE summarizes:

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.

The weakness was disclosed 06/14/2022. The advisory is available at gynvael.coldwind.pl. This vulnerability is traded as CVE-2022-33175 since 06/13/2022. Technical details are known, but there is no available exploit. This vulnerability is assigned to T1222 by the MITRE ATT&CK project.

Upgrading to version 3.30.30 eliminates this vulnerability.

Productinfo

Vendor

Name

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.2
VulDB Meta Temp Score: 7.1

VulDB Base Score: 4.7
VulDB Temp Score: 4.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 9.8
CNA Vector (MITRE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Permission
CWE: CWE-275 / CWE-266
ATT&CK: T1222

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: PDU 3.30.30

Timelineinfo

06/13/2022 🔍
06/14/2022 +1 days 🔍
06/14/2022 +0 days 🔍
06/14/2022 +0 days 🔍

Sourcesinfo

Advisory: gynvael.coldwind.pl
Status: Confirmed

CVE: CVE-2022-33175 (🔍)

Entryinfo

Created: 06/14/2022 10:13
Changes: 06/14/2022 10:13 (51)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!