Siemens PADS Standard/PADS Standard Plus PCB File Parser out-of-bounds write
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
7.0 | $5k-$25k | 0.00 |
A vulnerability classified as critical was found in Siemens PADS Standard and PADS Standard Plus (the affected version is unknown). Affected by this vulnerability is an unknown code of the component PCB File Parser. The manipulation with an unknown input leads to a out-of-bounds write vulnerability. The CWE definition for the vulnerability is CWE-787. The product writes data past the end, or before the beginning, of the intended buffer. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-051)
The weakness was shared 07/12/2022 as ssa-439148. It is possible to read the advisory at cert-portal.siemens.com. This vulnerability is known as CVE-2022-34286 since 06/22/2022. It demands that the victim is doing some kind of user interaction. The technical details are unknown and an exploit is not publicly available. The pricing for an exploit might be around USD $5k-$25k at the moment (estimation calculated on 07/21/2022).
The problem might be mitigated by replacing the product with as an alternative.
Product
Vendor
Name
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 7.0VulDB Meta Temp Score: 7.0
VulDB Base Score: 6.3
VulDB Temp Score: 6.2
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 7.8
NVD Vector: 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Out-of-bounds writeCWE: CWE-787 / CWE-119
ATT&CK: Unknown
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: AlternativeStatus: 🔍
0-Day Time: 🔍
Timeline
06/22/2022 🔍07/12/2022 🔍
07/12/2022 🔍
07/21/2022 🔍
Sources
Vendor: siemens.comAdvisory: ssa-439148
Status: Confirmed
CVE: CVE-2022-34286 (🔍)
Entry
Created: 07/12/2022 16:41Updated: 07/21/2022 15:53
Changes: 07/12/2022 16:41 (39), 07/21/2022 15:53 (18)
Complete: 🔍
No comments yet. Languages: en.