Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471 Access Point Setting hard-coded password
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
4.7 | $0-$5k | 0.14 |
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects an unknown part of the component Access Point Setting Handler. The manipulation with the input value 12345678
leads to a hard-coded password vulnerability. Using CWE to declare the problem leads to CWE-259. The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components. Impacted is confidentiality, integrity, and availability.
The weakness was shared 02/13/2023 by Jan Mahn as Balkonkraftwerke: Sicherheitslücke in Mikrowechselrichtern von Deye as confirmed article (Heise). The advisory is shared at heise.de. The vendor cooperated in the coordination of the public release. The article contains:
Als Nutzer verbindet man sich mit einem Access-Point, den der Wechselrichter aufspannt und nutzt dafür den Schlüssel 12345678. In der Weboberfläche trägt man die Zugangsdaten zum eigenen WLAN ein und schaltet den Access-Point dann ab oder ändert dessen Schlüssel. Dieser Zugang wird ja nicht mehr gebraucht, weil sich das Gerät fortan mit dem WLAN verbinden soll. Das Problem: Der Speichern-Button ist ohne Funktion, der Wechselrichter schließt den Access-Point nicht und auch 12345678 als Schlüssel lässt sich nicht ändern.The identification of this vulnerability is CVE-2023-0808. Technical details as well as a public exploit are known. MITRE ATT&CK project uses the attack technique T1078.001 for this issue.
The exploit is available at heise.de. It is declared as proof-of-concept.
Upgrading to version MW3_16U_5406_1.53 eliminates this vulnerability.
Product
Vendor
Name
Version
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 4.9VulDB Meta Temp Score: 4.7
VulDB Base Score: 3.9
VulDB Temp Score: 3.5
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 6.8
NVD Vector: 🔍
CNA Base Score: 3.9
CNA Vector (VulDB): 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Hard-coded passwordCWE: CWE-259 / CWE-255
CAPEC: 🔍
ATT&CK: 🔍
Local: Yes
Remote: No
Availability: 🔍
Access: Public
Status: Proof-of-Concept
Download: 🔍
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Upgrade: Inverter MW3_16U_5406_1.53
Timeline
02/13/2023 🔍02/13/2023 🔍
02/13/2023 🔍
03/10/2023 🔍
Sources
Advisory: Balkonkraftwerke: Sicherheitslücke in Mikrowechselrichtern von DeyeResearcher: Jan Mahn
Status: Confirmed
Coordinated: 🔍
CVE: CVE-2023-0808 (🔍)
scip Labs: https://www.scip.ch/en/?labs.20161013
Entry
Created: 02/13/2023 12:03 PMUpdated: 03/10/2023 09:50 PM
Changes: 02/13/2023 12:03 PM (44), 02/13/2023 12:05 PM (6), 03/10/2023 09:37 PM (2), 03/10/2023 09:50 PM (28)
Complete: 🔍
Cache ID: 34:F36:40
No comments yet. Languages: en.
Please log in to comment.