Schneider Electric EcoStruxure Control Expert 15.1 Console Server Service privileges management
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
5.4 | $0-$5k | 0.00 |
A vulnerability, which was classified as critical, has been found in Schneider Electric EcoStruxure Control Expert 15.1 (SCADA Software). This issue affects an unknown code of the component Console Server Service. The manipulation with an unknown input leads to a privileges management vulnerability. Using CWE to declare the problem leads to CWE-269. The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor. Impacted is availability. The summary by CVE is:
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
The weakness was disclosed 04/18/2023 as SEVD-2023-101-03. It is possible to read the advisory at https. The identification of this vulnerability is CVE-2023-1548 since 03/21/2023. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1068 according to MITRE ATT&CK.
Applying a patch is able to eliminate this problem.
Product
Type
Vendor
Name
Version
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 5.5VulDB Meta Temp Score: 5.4
VulDB Base Score: 5.5
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 5.5
CNA Vector (Schneider Electric SE): 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Privileges managementCWE: CWE-269 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍
Local: Yes
Remote: No
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔍
Timeline
03/21/2023 🔍04/18/2023 🔍
04/18/2023 🔍
04/18/2023 🔍
Sources
Vendor: schneider-electric.comAdvisory: SEVD-2023-101-03
Status: Confirmed
CVE: CVE-2023-1548 (🔍)
Entry
Created: 04/18/2023 08:52 PMChanges: 04/18/2023 08:52 PM (51)
Complete: 🔍
Cache ID: 18:484:40
No comments yet. Languages: en.
Please log in to comment.