Topaz SigPlus Pro ActiveX Control up to 3.94 memory corruption

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
9.5$0-$5k0.00

A vulnerability was found in Topaz SigPlus Pro ActiveX Control up to 3.94 and classified as very critical. Affected by this issue is an unknown code of the component ActiveX Control. The manipulation with an unknown input leads to a memory corruption vulnerability. Using CWE to declare the problem leads to CWE-119. The product performs operations on a memory buffer, but it can read from or write to a memory location that is outside of the intended boundary of the buffer. Impacted is confidentiality, integrity, and availability. CVE summarizes:

Topaz Systems SigPlus Pro ActiveX Control 3.95, and possibly other versions before 4.29, allows remote attackers to execute arbitrary code by calling the exposed unsafe (1) SetLogFilePath and (2) SigMessage methods to create arbitrary files with arbitrary content.

The weakness was shared 02/07/2011 by Dmitriy Pletnev with Secunia Research (Website). The advisory is available at xforce.iss.net. This vulnerability is handled as CVE-2011-0323. The attack may be launched remotely. No form of authentication is required for exploitation. The technical details are unknown and an exploit is not available. The structure of the vulnerability defines a possible price range of USD $0-$5k at the moment (estimation calculated on 10/13/2021).

The vulnerability scanner Nessus provides a plugin with the ID 51895 (SigPlus Pro ActiveX Control < 4.29 Multiple Vulnerabilities), which helps to determine the existence of the flaw in a target environment. It is assigned to the family Windows.

Upgrading to version 3.95 eliminates this vulnerability.

The vulnerability is also documented in the databases at X-Force (65117) and Tenable (51895). The entry 56355 is related to this item.

Productinfo

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 10.0
VulDB Meta Temp Score: 9.5

VulDB Base Score: 10.0
VulDB Temp Score: 9.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Memory corruption
CWE: CWE-119
ATT&CK: Unknown

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Nessus ID: 51895
Nessus Name: SigPlus Pro ActiveX Control < 4.29 Multiple Vulnerabilities
Nessus File: 🔍
Nessus Risk: 🔍
Nessus Family: 🔍

OpenVAS ID: 801753
OpenVAS Name: Topaz Systems SigPlus Pro ActiveX Control Multiple Vulnerabilities
OpenVAS File: 🔍
OpenVAS Family: 🔍

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SigPlus Pro ActiveX Control 3.95

Timelineinfo

01/06/2011 🔍
02/03/2011 +28 days 🔍
02/03/2011 +0 days 🔍
02/07/2011 +4 days 🔍
02/07/2011 +0 days 🔍
02/07/2011 +0 days 🔍
02/14/2011 +7 days 🔍
03/20/2015 +1495 days 🔍
10/13/2021 +2399 days 🔍

Sourcesinfo

Advisory: xforce.iss.net
Researcher: Dmitriy Pletnev
Organization: Secunia Research
Status: Not defined

CVE: CVE-2011-0323 (🔍)
X-Force: 65117
Vulnerability Center: 29753 - Topaz Systems SigPlus Pro ActiveX Control 3.95 Remote Arbitrary Code Execution Vulnerability, Medium
SecurityFocus: 46128 - SigPlus Pro ActiveX Control Multiple Vulnerabilities
Secunia: 42800

See also: 🔍

Entryinfo

Created: 03/20/2015 16:16
Updated: 10/13/2021 20:39
Changes: 03/20/2015 16:16 (58), 03/15/2017 12:45 (11), 10/13/2021 20:32 (3), 10/13/2021 20:39 (1)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Might our Artificial Intelligence support you?

Check our Alexa App!