Siemens SIMATIC S7-1500 Cpu up to 1.1.1 redirect

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.1$0-$5k0.00

A vulnerability classified as problematic was found in Siemens SIMATIC S7-1500 Cpu up to 1.1.1 (SCADA Software). The CWE definition for the vulnerability is CWE-601. A web application accepts a user-controlled input that specifies a link to an external site, and uses that link in a Redirect. This simplifies phishing attacks. As an impact it is known to affect integrity. CVE summarizes:

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.

The weakness was disclosed 03/16/2014 by Positive Technologies (ryan) with Positive Technologies (Website). The advisory is available at ics-cert.us-cert.gov. This vulnerability was named CVE-2014-2248 since 02/28/2014. The attack can be initiated remotely. No form of authentication is required for a successful exploitation. The technical details are unknown and an exploit is not available. This vulnerability is assigned to T1204.001 by the MITRE ATT&CK project.

Upgrading to version 1.1.2 eliminates this vulnerability.

The entries 66688, 66687, 66686 and 66685 are pretty similar.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.3
VulDB Meta Temp Score: 5.1

VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Redirect
CWE: CWE-601
ATT&CK: T1204.001

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SIMATIC S7-1500 Cpu 1.1.2

Timelineinfo

02/28/2014 🔍
03/12/2014 +12 days 🔍
03/16/2014 +4 days 🔍
03/16/2014 +0 days 🔍
03/24/2015 +373 days 🔍
02/03/2022 +2508 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-456423
Researcher: Positive Technologies (ryan)
Organization: Positive Technologies
Status: Not defined
Confirmation: 🔍

CVE: CVE-2014-2248 (🔍)
SecurityFocus: 66190 - Siemens SIMATIC S7-1500 CVE-2014-2248 Arbitrary URI Redirection Vulnerability

See also: 🔍

Entryinfo

Created: 03/24/2015 15:54
Updated: 02/03/2022 18:48
Changes: 03/24/2015 15:54 (48), 02/28/2018 08:06 (7), 02/03/2022 18:41 (3), 02/03/2022 18:48 (2)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!