Schneider Electric SCADA Expert ClearSCADA up to 2013 cross site scripting
CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
---|---|---|
3.5 | $0-$5k | 0.00 |
A vulnerability was found in Schneider Electric SCADA Expert ClearSCADA up to 2013 (SCADA Software). It has been classified as problematic. This affects an unknown function. The manipulation with an unknown input leads to a cross site scripting vulnerability. CWE is classifying the issue as CWE-79. The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. This is going to have an impact on integrity. The summary by CVE is:
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
The weakness was published 09/18/2014 (Website). It is possible to read the advisory at ics-cert.us-cert.gov. This vulnerability is uniquely identified as CVE-2014-5411 since 08/22/2014. It is possible to initiate the attack remotely. The successful exploitation requires a authentication. It demands that the victim is doing some kind of user interaction. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1059.007 according to MITRE ATT&CK.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product. Furthermore it is possible to detect and prevent this kind of attack with TippingPoint and the filter 16996.
The vulnerability is also documented in the vulnerability database at X-Force (96199). Similar entries are available at 71297 and 71296.
Product
Type
Vendor
Name
Version
License
CPE 2.3
CPE 2.2
CVSSv4
VulDB CVSS-B Score: 🔍VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 3.5VulDB Meta Temp Score: 3.5
VulDB Base Score: 3.5
VulDB Temp Score: 3.5
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv2
AV | AC | Au | C | I | A |
---|---|---|---|---|---|
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
---|---|---|---|---|---|
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
unlock | unlock | unlock | unlock | unlock | unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Cross site scriptingCWE: CWE-79 / CWE-74 / CWE-707
CAPEC: 🔍
ATT&CK: 🔍
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
0-Day | unlock | unlock | unlock | unlock |
---|---|---|---|---|
Today | unlock | unlock | unlock | unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
TippingPoint: 🔍
Fortigate IPS: 🔍
Timeline
08/22/2014 🔍09/17/2014 🔍
09/18/2014 🔍
09/18/2014 🔍
11/04/2014 🔍
03/26/2015 🔍
06/11/2017 🔍
Sources
Vendor: schneider-electric.comAdvisory: ics-cert.us-cert.gov
Status: Not defined
CVE: CVE-2014-5411 (🔍)
X-Force: 96199
Vulnerability Center: 46886 - Schneider Electric SCADA Expert ClearSCADA 2010 R3 - 2014 R1 Multiple XSS Vulnerabilities, Low
See also: 🔍
Entry
Created: 03/26/2015 15:08Updated: 06/11/2017 04:56
Changes: 03/26/2015 15:08 (54), 06/11/2017 04:56 (2)
Complete: 🔍
No comments yet. Languages: en.