GE Healthcare Revolution XQi adw3.1 Acquisition Workstation Password credentials management

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.3$0-$5k0.00

A vulnerability was found in GE Healthcare Revolution XQi adw3.1 (Medical Device Software) and classified as critical. Affected by this issue is an unknown functionality of the component Acquisition Workstation. The manipulation of the argument Password with the input value adw3 leads to a credentials management vulnerability. Using CWE to declare the problem leads to CWE-255. Impacted is confidentiality, integrity, and availability. CVE summarizes:

The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.

The weakness was published 08/04/2015 (Website). The advisory is available at twitter.com. This vulnerability is handled as CVE-2010-5310 since 09/29/2014. The attack may be launched remotely. No form of authentication is required for exploitation. Technical details are known, but there is no available exploit. This vulnerability is assigned to T1552 by the MITRE ATT&CK project.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Similar entries are available at 76898, 76899, 76900 and 76901.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.3
VulDB Meta Temp Score: 7.3

VulDB Base Score: 7.3
VulDB Temp Score: 7.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Credentials management
CWE: CWE-255
ATT&CK: T1552

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

09/29/2014 🔍
08/04/2015 +309 days 🔍
08/04/2015 +0 days 🔍
08/05/2015 +1 days 🔍
09/04/2017 +761 days 🔍

Sourcesinfo

Vendor: ge.com

Advisory: twitter.com
Status: Not defined
Confirmation: 🔍

CVE: CVE-2010-5310 (🔍)
See also: 🔍

Entryinfo

Created: 08/05/2015 10:06
Updated: 09/04/2017 09:23
Changes: 08/05/2015 10:06 (44), 09/04/2017 09:23 (8)
Complete: 🔍

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?