Hospira Schwachstellen

Zeitverlauf

Typ

Produkt

Hospira LifeCare PCA Infusion System7
Hospira Symbiq Infusion System5
Hospira MedNet4
Hospira Plum A+ Infusion System4
Hospira Plum A+3 Infusion System4

Massnahmen

Official Fix9
Temporary Fix0
Workaround5
Unavailable0
Not Defined3

Ausnutzbarkeit

High0
Functional0
Proof-of-Concept0
Unproven0
Not Defined17

Zugriffsart

Not Defined0
Physical0
Local2
Adjacent3
Network12

Authentisierung

Not Defined0
High0
Low2
None15

Benutzeraktivität

Not Defined0
Required0
None17

C3BM Index

CVSSv3 Base

≤10
≤20
≤30
≤41
≤51
≤62
≤70
≤89
≤91
≤103

CVSSv3 Temp

≤10
≤20
≤30
≤41
≤51
≤62
≤73
≤86
≤91
≤103

VulDB

≤10
≤20
≤30
≤41
≤51
≤62
≤73
≤87
≤91
≤102

NVD

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤83
≤91
≤104

CNA

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Hersteller

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Research

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Exploit 0-day

<1k0
<2k8
<5k8
<10k0
<25k0
<50k1
<100k0
≥100k0

Exploit heute

<1k17
<2k0
<5k0
<10k0
<25k0
<50k0
<100k0
≥100k0

Exploitmarktvolumen

🔴 CTI Aktivitäten

Affected Products (6): LifeCare PCA Infusion System (7), Lifecare PCA Infusion Pump (1), MedNet (4), Plum A+3 Infusion System (4), Plum A+ Infusion System (4), Symbiq Infusion System (5)

VeröffentlichtBaseTempSchwachstelleProdAusMasEPSSCTICVE
26.03.20198.58.4Hospira MedNet JBoss Enterprise Application Platform erweiterte RechteUnbekanntNot DefinedOfficial Fix0.001900.04CVE-2014-5401
25.03.20198.08.0Hospira Plum A+ Infusion System schwache AuthentisierungMedical Device SoftwareNot DefinedWorkaround0.002130.04CVE-2015-3956
25.03.20199.39.2Hospira Plum A+ Infusion System Telnet Service erweiterte RechteMedical Device SoftwareNot DefinedWorkaround0.002130.00CVE-2015-3954
25.03.20198.08.0Hospira Plum A+ Infusion System schwache AuthentisierungMedical Device SoftwareNot DefinedWorkaround0.002130.02CVE-2015-3953
25.03.20197.47.4Hospira Plum A+ Infusion System Information DisclosureMedical Device SoftwareNot DefinedNot Defined0.001620.00CVE-2015-3952
25.03.20197.47.1Hospira LifeCare PCA Infusion System Information DisclosureMedical Device SoftwareNot DefinedOfficial Fix0.001620.04CVE-2015-1012
23.03.20197.57.5Hospira Symbiq Infusion System erweiterte RechteMedical Device SoftwareNot DefinedNot Defined0.002070.04CVE-2015-3965
22.01.20167.37.0Hospira LifeCare PCA Infusion System Communication Engine PufferüberlaufMedical Device SoftwareNot DefinedOfficial Fix0.002070.02CVE-2015-7909
06.07.20155.35.2Hospira LifeCare PCA Infusion System TCP Packet Denial of ServiceMedical Device SoftwareNot DefinedWorkaround0.005200.00CVE-2015-3958
06.07.20155.95.7Hospira LifeCare PCA Infusion System Private Key Storage erweiterte RechteMedical Device SoftwareNot DefinedOfficial Fix0.001030.04CVE-2015-3957

7 weitere Einträge werden nicht mehr angezeigt

Are you interested in using VulDB?