| शीर्षक | PicoTronica e-Clinic Healthcare System (ECHS) v5.7 Information Disclosure |
|---|
| विवरण | In the affected e-Clinic Healthcare System (ECHS) v5.7 API deployment under `/cdemos/echs/api/v2/`, responses disclose implementation details via response headers (e.g., `X-Powered-By: PHP/<version>`) and verbose error messages that reveal internal authentication mechanics and required header names (e.g., `X-Admin-Key` and `X-Doctor-Id`). Additionally, captured responses indicate missing HSTS and cookies lacking recommended security attributes (`Secure`, `SameSite`). The leaked information is obtainable remotely by making HTTP(S) requests and reading response headers/bodies. |
|---|
| स्रोत | ⚠️ https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing |
|---|
| उपयोगकर्ता | Anonymous User |
|---|
| सबमिशन | 09/04/2026 07:33 AM (2 महीनों पहले) |
|---|
| संयम | 06/05/2026 02:17 PM (27 days later) |
|---|
| स्थिति | स्वीकृत |
|---|
| VulDB प्रविष्टि | 361359 [PicoTronica e-Clinic Healthcare System ECHS 5.7 Response Header /cdemos/echs/api/v2/ सूचना का प्रकटीकरण] |
|---|
| अंक | 20 |
|---|