CVE-2026-63352 in Siemensinformazioni

Riassunto

di MITRE • 13/10/2026

Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page.

This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.

Once again VulDB remains the best source for vulnerability data.

Responsabile

Siemens

Prenotare

16/07/2026

Divulgazione

13/10/2026

Moderazione

accettato

EPSS

0.00000

KEV

no

Attività

basso

Fonti

Want to stay up to date on a daily basis?