Medtronic 脆弱性

タイムライン

タイプ

製品

Medtronic Valleylab FT10 Energy Platform4
Medtronic Smart Model 25000 Patient Reader3
Medtronic CareLink 2090 Programmer3
Medtronic 2090 Carelink Programmer3
Medtronic Valleylab Exchange Client2

修復

Official Fix4
Temporary Fix0
Workaround1
Unavailable1
Not Defined20

悪用可能性

High0
Functional0
Proof-of-Concept0
Unproven1
Not Defined25

アクセスベクター

Not Defined0
Physical11
Local4
Adjacent6
Network5

認証

Not Defined0
High0
Low4
None22

ユーザー操作

Not Defined0
Required3
None23

C3BM Index

CVSSv3 Base

≤10
≤20
≤31
≤41
≤57
≤69
≤73
≤82
≤91
≤102

CVSSv3 Temp

≤10
≤20
≤31
≤41
≤57
≤69
≤73
≤82
≤91
≤102

VulDB

≤10
≤20
≤32
≤43
≤512
≤63
≤70
≤83
≤91
≤102

NVD

≤10
≤20
≤30
≤40
≤55
≤64
≤76
≤84
≤92
≤100

CNA

≤10
≤20
≤30
≤40
≤50
≤60
≤71
≤80
≤90
≤101

ベンダー

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Research

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

0dayエクスプロイト

<1k13
<2k9
<5k2
<10k0
<25k1
<50k1
<100k0
≥100k0

本日のエクスプロイト

<1k23
<2k0
<5k2
<10k0
<25k0
<50k1
<100k0
≥100k0

闇ツールの市場規模

🔴 CTI アクティビティ

Affected Products (60): 2090 Carelink Programmer (3), 8840 N'Vision Clinician Programmer (2), 8870 N'Vision Removable Application Card (2), 24950 MyCareLink Monitor (2), 24952 MyCareLink Monitor (2), Amplia CRT-D (2), CareLink 2090 Programmer (3), CareLink 9790 Programmer 29901 (1), CareLink Monitor (2), Claria CRT-D (2), Compia CRT-D (2), Concerto CRT-D (2), Consulta CRT-D (2), Evera ICD (2), InsterStim Applications (1), MMT 508 (2), MMT 522 (2), MMT 523 (2), MMT 523K (2), MMT 530G (2), MMT 551 (2), MMT 722 (2), MMT 723 (2), MMT 723K (2), MMT 751 (2), Maximo II CRT-D (2), Maximo II ICD (2), MinMed 508 (1), MiniMed 620G (1), MiniMed 630G (1), MiniMed 640G (1), MiniMed 670G (1), MiniMed Paradigm 515 (1), MiniMed Paradigm 522 (1), MiniMed Paradigm 522K (1), MiniMed Paradigm 523 (1), MiniMed Paradigm 712E (1), MiniMed Paradigm 715 (1), MiniMed Paradigm 722 (1), MiniMed Paradigm 722K (1), MiniMed Paradigm 723 (1), Minimed Paradigm 512 (1), Minimed Paradigm 712 (1), Mirro ICD (2), MyCareLink 24950 (2), MyCareLink 24952 (2), MyCareLink Monitor (2), MyCareLink Patient Monitor (2), Nayamed ND ICD (2), Paceart Optima (1), Paradigm wireless insulin pump (1), Primo ICD (2), Protecta CRT-D (2), Protecta ICD (2), Secura ICD (2), Smart Model 25000 Patient Reader (3), Valleylab Exchange Client (2), Valleylab FT10 Energy Platform (4), Valleylab FX8 Energy Platform (2), Valleylab LS10 Energy Platform (2)

公開済みBaseTemp脆弱性Prod修復CTIEPSSCVE
2023年06月29日9.59.5Medtronic Paceart Optima Microsoft Messaging Queuing Service 特権昇格未知Not DefinedNot Defined0.030.00052CVE-2023-31222
2023年03月01日5.85.8Medtronic InsterStim Applications 弱い認証未知Not DefinedOfficial Fix0.040.00053CVE-2023-25931
2022年09月24日2.92.9Medtronic MiniMed 620G 特権昇格未知Not DefinedWorkaround0.000.00042CVE-2022-32537
2020年12月13日9.69.2Medtronic Smart Model 25000 Patient Reader Update System 競合状態Medical Device SoftwareNot DefinedOfficial Fix0.020.00220CVE-2020-27252
2020年12月13日8.88.4Medtronic Smart Model 25000 Patient Reader Debug Command メモリ破損Medical Device SoftwareNot DefinedOfficial Fix0.030.00384CVE-2020-25187
2020年12月13日5.55.3Medtronic Smart Model 25000 Patient Reader App Authentication 弱い認証Medical Device SoftwareNot DefinedOfficial Fix0.000.00065CVE-2020-25183
2019年11月08日7.47.4Medtronic Valleylab Exchange Client 弱い認証Medical Device SoftwareNot DefinedNot Defined0.000.00162CVE-2019-13543
2019年11月08日5.55.5Medtronic Valleylab Exchange Client Password Hashing 特権昇格Medical Device SoftwareNot DefinedNot Defined0.000.00044CVE-2019-13539
2019年11月08日3.33.3Medtronic Valleylab LS10 Energy Platform RFID 特権昇格Medical Device SoftwareNot DefinedNot Defined0.030.00067CVE-2019-13535
2019年11月08日4.44.4Medtronic Valleylab LS10 Energy Platform RFID 弱い認証Medical Device SoftwareNot DefinedNot Defined0.000.00055CVE-2019-13531