| タイトル | iptime c200 1.092 Command Injection |
|---|
| 説明 | The sub_409054 function is triggered via the ApplyRestore endpoint when the device processes a backup configuration file (.tar). This function reads configuration values from /etc/iconfig.cfg through sub_408F90, which performs no sanitization or escaping of special shell characters. The values are then directly interpolated into a snprintf-built command string and executed via popen().An attacker with a valid session can craft a malicious configuration archive containing backtick-injected shell commands in the sysset_userid or sysset_userpw fields. These commands are executed with root privileges when the router processes the restore operation. |
|---|
| ソース | ⚠️ https://github.com/glkfc/IoT-Vulnerability/blob/main/iptime/c200/sub_409054_vulnerability_report_EN.md |
|---|
| ユーザー | jfkk (UID 79868) |
|---|
| 送信 | 2026年04月19日 08:53 (2 月 ago) |
|---|
| モデレーション | 2026年05月05日 08:33 (16 days later) |
|---|
| ステータス | 承諾済み |
|---|
| VulDBエントリ | 361112 [EFM ipTIME C200 迄 1.092 ApplyRestore Endpoint /cgi/iux_set.cgi sub_408F90 RestoreFile 特権昇格] |
|---|
| ポイント | 20 |
|---|