| 제목 | Shenzhen Ningyuanda Technology Co., Ltd. TC155 IP Camera Firmware version: 57.0.2.0 Unauthenticated Hard Reset via ONVIF SetSystemFactoryDefault |
|---|
| 설명 | The TC155 IP Camera exposes the ONVIF Device Management service without authentication. An attacker on the local network can invoke the SetSystemFactoryDefault action with FactoryDefault=Hard, resulting in a full factory reset, loss of configuration, and temporary loss of availability. No credentials are required. |
|---|
| 원천 | ⚠️ https://github.com/pwnpwnpur1n/IoT-advisories/blob/main/TC155-Unauth-Hard-Reset.md |
|---|
| 사용자 | keroomi (UID 62127) |
|---|
| 제출 | 2025. 12. 05. AM 11:49 (6 개월 ago) |
|---|
| 모더레이션 | 2025. 12. 15. PM 09:39 (10 days later) |
|---|
| 상태 | 수락 |
|---|
| VulDB 항목 | 336521 [Ningyuanda TC155 57.0.2.0 ONVIF Device Management Service /onvif/device_service FactoryDefault 권한 상승] |
|---|
| 포인트들 | 18 |
|---|