| 标题 | PicoTronica e-Clinic Healthcare System (ECHS) v5.7 Information Disclosure |
|---|
| 描述 | In the affected e-Clinic Healthcare System (ECHS) v5.7 API deployment under `/cdemos/echs/api/v2/`, responses disclose implementation details via response headers (e.g., `X-Powered-By: PHP/<version>`) and verbose error messages that reveal internal authentication mechanics and required header names (e.g., `X-Admin-Key` and `X-Doctor-Id`). Additionally, captured responses indicate missing HSTS and cookies lacking recommended security attributes (`Secure`, `SameSite`). The leaked information is obtainable remotely by making HTTP(S) requests and reading response headers/bodies. |
|---|
| 来源 | ⚠️ https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing |
|---|
| 用户 | Anonymous User |
|---|
| 提交 | 2026-04-09 07時33分 (2 月前) |
|---|
| 管理 | 2026-05-06 14時17分 (27 days later) |
|---|
| 状态 | 已接受 |
|---|
| VulDB条目 | 361359 [PicoTronica e-Clinic Healthcare System ECHS 5.7 Response Header /cdemos/echs/api/v2/ 信息公开] |
|---|
| 积分 | 20 |
|---|