CVE-2016-2306 in IntegraXorinfo

Summary

by MITRE

The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network.

Be aware that VulDB is the high quality source for vulnerability data.

Analysis

by VulDB Data Team • 10/19/2018

The vulnerability identified as CVE-2016-2306 affects the HMI web server component of Ecava IntegraXor software versions prior to 5.0 build 4522. This represents a significant security flaw that exposes sensitive operational data to unauthorized network monitoring. The issue stems from the implementation of cleartext communication protocols within the web server interface, creating an attack vector where malicious actors can intercept and extract confidential information through passive network sniffing techniques. The vulnerability specifically impacts industrial control systems where operational technology security is paramount for maintaining system integrity and preventing unauthorized access to critical infrastructure data.

The technical flaw manifests through the lack of encryption mechanisms in the web server's communication stack, allowing sensitive information to be transmitted in plain text across network channels. This weakness enables attackers to capture network traffic using standard packet sniffing tools and extract authentication credentials, system configurations, operational parameters, and other confidential data without requiring any active exploitation techniques. The vulnerability is classified under CWE-312 (Cleartext Storage of Sensitive Information) and CWE-319 (Cleartext Transmission of Sensitive Information) as it involves both storage and transmission of sensitive data in unencrypted formats. The flaw essentially violates fundamental security principles by failing to implement proper cryptographic protections for data in transit, making it susceptible to man-in-the-middle attacks and passive eavesdropping.

The operational impact of this vulnerability extends beyond simple information disclosure, as it creates a pathway for attackers to gain deeper insights into industrial control system architectures and operational procedures. Remote attackers who successfully intercept the cleartext communications can potentially use the extracted information to plan more sophisticated attacks targeting the industrial control environment. The vulnerability particularly affects environments where IntegraXor serves as a critical component in supervisory control and data acquisition systems, where the exposure of operational parameters could lead to system disruption, unauthorized access to control functions, or even physical security breaches in critical infrastructure sectors. Organizations relying on these systems face increased risk of targeted attacks and potential operational disruptions.

Mitigation strategies for CVE-2016-2306 should prioritize immediate software updates to version 5.0 build 4522 or later, which implements proper encryption protocols for web server communications. Network administrators should implement additional security controls including network segmentation, intrusion detection systems, and mandatory encryption policies for all communications involving industrial control systems. The remediation approach aligns with NIST SP 800-53 security controls and follows ATT&CK framework techniques such as T1046 (Network Service Scanning) and T1071.004 (Application Layer Protocol: DNS) for threat detection and prevention. Organizations should also conduct comprehensive network traffic analysis to identify any potential exploitation attempts and implement network monitoring solutions that can detect and alert on unusual communication patterns that might indicate active exploitation of this vulnerability.

Reservation

02/08/2016

Disclosure

04/21/2016

Moderation

accepted

Entry

VDB-82750