CVE-2017-12180 in X11 Serverinfo

Summary

by MITRE

xorg-x11-server before 1.19.5 was missing length validation in XFree86 VidModeExtension allowing malicious X client to cause X server to crash or possibly execute arbitrary code.

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Analysis

by VulDB Data Team • 08/29/2025

The vulnerability identified as CVE-2017-12180 affects the xorg-x11-server package version 1.19.4 and earlier, specifically within the XFree86 VidModeExtension implementation. This flaw represents a critical security issue that could potentially allow remote attackers to execute arbitrary code on systems running affected X server versions. The vulnerability stems from inadequate input validation mechanisms within the video mode extension functionality that governs display configuration parameters in X Window System environments.

The technical root cause of this vulnerability lies in the absence of proper length validation checks within the XFree86 VidModeExtension code. When a malicious X client sends specially crafted requests to the X server through this extension, the server fails to validate the length of incoming data structures before processing them. This omission creates a classic buffer over-read condition that can be exploited to trigger memory corruption. According to CWE classification, this vulnerability maps to CWE-129, which covers insufficient validation of length of data structures, and CWE-787, which addresses out-of-bounds write operations. The flaw operates at the protocol level where X server extensions handle client requests, making it particularly dangerous as it can be exploited by any client that can establish a connection to the X server.

The operational impact of this vulnerability extends beyond simple denial of service scenarios. While the initial exploitation might cause the X server to crash and restart, more sophisticated attacks could leverage the memory corruption to achieve arbitrary code execution. This capability allows attackers to potentially gain full control over the affected system, especially when the X server is running with elevated privileges or when users with administrative access are logged in. The vulnerability affects systems where the X Window System is actively used, particularly those running graphical environments that utilize the VidMode extension for display configuration. Attackers could exploit this through network-based X11 forwarding scenarios or by gaining local access to systems where the X server is running, making it relevant for both remote and local attack vectors.

Mitigation strategies for CVE-2017-12180 should prioritize immediate patching of affected systems with the updated xorg-x11-server package version 1.19.5 or later. Organizations should also implement network segmentation to restrict access to X server ports, particularly when X11 forwarding is not required for legitimate operations. The implementation of access controls through X server configuration files and the use of X11 security extensions can help reduce the attack surface. Additionally, monitoring for suspicious X client behavior and implementing intrusion detection systems that can identify malformed X protocol requests will aid in early detection of exploitation attempts. According to ATT&CK framework, this vulnerability maps to T1059 for command and scripting interpreter and T1068 for exploit for privilege escalation, making comprehensive monitoring and access control essential defensive measures. System administrators should also consider disabling unnecessary X server extensions and implementing principle of least privilege for X server access to minimize potential impact from successful exploitation attempts.

Reservation

08/01/2017

Disclosure

01/24/2018

Moderation

accepted

CPE

ready

EPSS

0.00502

KEV

no

Activities

very low

Sources

Do you want to use VulDB in your project?

Use the official API to access entries easily!