CVE-2022-25785 in SiteManagerinfo

Summary

by MITRE • 05/04/2022

Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Analysis

by VulDB Data Team • 05/07/2022

The CVE-2022-25785 vulnerability represents a critical stack-based buffer overflow flaw within Secomea SiteManager software that poses significant security risks to industrial control systems. This vulnerability specifically affects all versions of SiteManager prior to version 9.7, making it a widespread concern for organizations relying on older installations. The flaw manifests when a logged-in or local user interacts with the system, creating a pathway for arbitrary code execution that could fundamentally compromise the integrity of the affected environment.

This buffer overflow vulnerability stems from improper input validation within the SiteManager application's memory handling mechanisms. When legitimate users perform certain operations within the system, the application fails to properly bounds-check data inputs before copying them into fixed-size stack buffers. The technical implementation violates fundamental security principles by allowing attackers to overwrite adjacent memory locations, potentially corrupting program execution flow and enabling malicious code injection. The vulnerability aligns with CWE-121 Stack-based Buffer Overflow, which specifically addresses buffer overflows occurring in stack memory regions where insufficient bounds checking permits data to overwrite adjacent memory locations.

The operational impact of this vulnerability extends beyond simple system instability, as it provides attackers with a direct path to execute arbitrary code on affected systems. This capability enables adversaries to escalate privileges, install persistent backdoors, or manipulate industrial processes that rely on SiteManager for network management and device control. For organizations utilizing Secomea SiteManager in critical infrastructure environments, this vulnerability represents a severe threat to operational technology security, potentially allowing attackers to gain unauthorized access to industrial control systems and disrupt critical operations.

Organizations should prioritize immediate remediation by upgrading to SiteManager version 9.7 or later, which contains the necessary patches to address the buffer overflow vulnerability. Additionally, implementing network segmentation and access controls can help limit the potential impact of exploitation, while monitoring for anomalous behavior patterns may aid in early detection of attempted exploitation. Security teams should also conduct comprehensive vulnerability assessments to identify all instances of affected SiteManager installations within their environments, ensuring complete remediation across all operational systems. The vulnerability demonstrates the critical importance of maintaining up-to-date industrial control system software and implementing robust security practices to protect against memory corruption attacks that could compromise operational technology infrastructure.

Responsible

Secomea A/S

Reservation

02/22/2022

Disclosure

05/04/2022

Moderation

accepted

CPE

ready

EPSS

0.00919

KEV

no

Activities

very low

Sources

Want to stay up to date on a daily basis?

Enable the mail alert feature now!