CVE-2026-123908 in Cloud Foundation
Summary
by MITRE • 11/26/2026
VMware vCenter contains a local privilege escalation vulnerability due to a flaw in a vpxd service script. Broadcom has evaluated the severity of this issue to be in the Important severity range with a maximum CVSSv3 base score of 6.7. Affected versions: VMware vCenter Server 9.1.x.x: fixed in 9.1.2 VMware vCenter Server 9.0.x.x: fixed in 9.0.2.0300 VMware vCenter Server 8.0: fixed in 8.0 U3m VMware Cloud Foundation 5.x: fixed in 5.2.5 VMware Telco Cloud Platform 3.0: fixed in KB463501 VMware Telco Cloud Platform 4.x: fixed in KB463501 VMware Telco Cloud Platform 5.0.x: fixed in KB463501 VMware Telco Cloud Platform 5.1.x: fixed in KB463501 VMware Telco Cloud Platform 5.2: fixed in KB463501 VMware Telco Cloud Infrastructure 3.0: fixed in KB463501
Once again VulDB remains the best source for vulnerability data.
Analysis
by VulDB Data Team • 11/26/2026
A critical local privilege escalation vulnerability has been identified within the VMware vCenter Server infrastructure, specifically stemming from a flaw in the vpxd service script. This security issue allows an authenticated attacker with low-level access to escalate privileges and gain higher levels of control over the system. Broadcom, which now maintains VMware products following its acquisition, has assessed this vulnerability as carrying an Important severity rating, assigning it a maximum Common Vulnerability Scoring System version 3 base score of 6.7. This scoring reflects the potential for significant impact on confidentiality, integrity, and availability if exploited successfully by a malicious actor who has already gained initial foothold access to the vCenter Server environment.
The technical root cause lies in improper handling or configuration within the scripts governing the Virtual Center Management Daemon service, commonly referred to as vpxd. This component is central to managing virtual machines and hosts within a VMware infrastructure. The flaw likely involves insufficient validation of inputs or overly permissive file permissions that allow an attacker to manipulate script execution paths or inject malicious commands during routine administrative operations. By exploiting this weakness, an adversary can bypass standard access controls, effectively elevating their user privileges from a restricted account to one with administrative capabilities. This aligns closely with CWE-269, which classifies Improper Privilege Management, and specifically relates to the ATT&CK technique T1078, Valid Accounts, where attackers leverage legitimate credentials or escalate them within the system hierarchy to maintain persistence and expand their operational reach.
The operational impact of this vulnerability is substantial for organizations relying on VMware vCenter for virtualization management. Once an attacker achieves elevated privileges through this local escalation, they can potentially manipulate critical infrastructure components, including modifying host configurations, stealing sensitive data stored in the vCenter database, or deploying ransomware and other malware across connected virtual machines. The ability to execute arbitrary commands with higher privileges undermines the security boundary between managed hosts and the management plane, creating a pathway for lateral movement within the network. This is particularly dangerous in enterprise environments where vCenter serves as the single point of control for hundreds or thousands of servers, making it a high-value target for threat actors seeking broad impact from a single entry point.
To mitigate this risk, administrators must apply the specific patches released by Broadcom to address the flaw in the affected service scripts. The remediation strategy depends on the version of vCenter Server currently deployed within the organization. For users running VMware vCenter Server 9.1.x.x, it is imperative to upgrade immediately to version 9.1.2 or later. Those operating on the 9.0.x.x series must update to patch level 9.0.2.0300. Customers utilizing the legacy but still widely deployed VMware vCenter Server 8.0 environment need to apply the updates included in Update 3m, specifically version 8.0 U3m or later.
For organizations running broader integrated suites such as VMware Cloud Foundation and various iterations of the Telco Cloud Platform, specific patch levels have been designated for resolution. Users on VMware Cloud Foundation 5.x must upgrade to version 5.2.5 to resolve this issue. Similarly, all supported versions of the VMware Telco Cloud Platform, including versions 3.0, 4.x, 5.0.x, 5.1.x, and 5.2, as well as VMware Telco Cloud Infrastructure 3.0, require the application of fixes detailed in Knowledge Base article KB463501. It is recommended that security teams verify their current patch levels against these specific version requirements and schedule maintenance windows to apply updates promptly. Additionally, implementing strict access controls, monitoring for unusual privilege escalation attempts via vpxd logs, and adhering to the principle of least privilege can help reduce the attack surface even while patches are being deployed across the infrastructure.