CVE-2026-136554 in RX3
Summary
by MITRE • 11/25/2026
A flaw has been found in Tenda RX3 16.03.13.11_multi. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet of the component httpd. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used.
Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
Analysis
by VulDB Data Team • 11/27/2026
The vulnerability identified in Tenda RX3 firmware version 16.03.13.11_multi represents a critical security flaw within the device's embedded web server component, specifically affecting the httpd service. This issue centers on the fromSysToolRestoreSet function located in the /goform/SysToolRestoreSet endpoint, which is responsible for handling system restoration and configuration reset operations. The core technical deficiency lies in an improper authentication mechanism that fails to enforce access controls before processing sensitive administrative commands. By exploiting this gap, an attacker can bypass required authentication checks, effectively gaining unauthorized control over critical device settings without valid credentials. This type of flaw is a classic example of broken access control, where the application logic does not adequately verify the identity or privileges of the user initiating the request prior to executing state-changing operations.
From a technical perspective, this vulnerability aligns with CWE-287, which describes Improper Authentication, and often overlaps with CWE-306 regarding Missing Authentication for Critical Function. The /goform/ interface is typical in embedded Linux devices like routers, where CGI scripts handle user input directly from HTTP requests. In this specific instance, the lack of session validation or token verification allows remote actors to invoke system-level functions that should be restricted to authenticated administrators. Since the exploit has been published and demonstrated publicly, the risk landscape shifts significantly from theoretical vulnerability to active exploitation in the wild. Attackers can leverage automated tools to scan for vulnerable devices on the internet and execute these requests without any prior interaction or credential theft, making this a high-severity remote code execution vector when combined with other potential flaws in the device's firmware stack.
The operational impact of this vulnerability is severe due to its remote nature and the criticality of the affected function. An attacker who successfully exploits this flaw can manipulate system settings, potentially disabling security features such as firewalls or Wi-Fi encryption, changing administrative passwords, or redirecting traffic through malicious DNS servers. This level of control facilitates broader attacks including man-in-the-middle scenarios, data interception, and the incorporation of the device into botnets for distributed denial-of-service campaigns. The ATT&CK framework categorizes this behavior under Initial Access techniques involving Exploitation for Remote Code Execution, specifically leveraging publicly available exploits against known vulnerable software versions. Furthermore, once inside, the attacker may proceed with Persistence mechanisms by modifying startup scripts or configuration files to maintain access even after reboots, highlighting the cascading risks associated with initial authentication bypasses in IoT devices.
Mitigation strategies must prioritize immediate remediation through firmware updates provided by Tenda that address this specific authentication gap. Organizations and individual users should verify their device version against known vulnerable lists and apply patches as soon as they are available from official channels. In environments where patching is not immediately feasible, network segmentation can help isolate affected devices from critical internal networks to limit lateral movement potential. Additionally, disabling remote management features on the router interface reduces the attack surface by preventing external access to administrative ports entirely. Security monitoring tools should be configured to detect anomalous HTTP requests targeting /goform/ endpoints with unusual parameters indicative of exploitation attempts for system restoration or configuration changes. Regular vulnerability scanning and asset inventory maintenance are essential to ensure that all IoT devices remain updated against evolving threats in the embedded systems landscape.