| Titel | PicoTronica e-Clinic Healthcare System (ECHS) v5.7 Information Disclosure |
|---|
| Beschreibung | In the affected e-Clinic Healthcare System (ECHS) v5.7 API deployment under `/cdemos/echs/api/v2/`, responses disclose implementation details via response headers (e.g., `X-Powered-By: PHP/<version>`) and verbose error messages that reveal internal authentication mechanics and required header names (e.g., `X-Admin-Key` and `X-Doctor-Id`). Additionally, captured responses indicate missing HSTS and cookies lacking recommended security attributes (`Secure`, `SameSite`). The leaked information is obtainable remotely by making HTTP(S) requests and reading response headers/bodies. |
|---|
| Quelle | ⚠️ https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing |
|---|
| Benutzer | Anonymous User |
|---|
| Einreichung | 09.04.2026 07:33 (vor 2 Monaten) |
|---|
| Moderieren | 06.05.2026 14:17 (27 days later) |
|---|
| Status | Akzeptiert |
|---|
| VulDB Eintrag | 361359 [PicoTronica e-Clinic Healthcare System ECHS 5.7 Response Header /cdemos/echs/api/v2/ Information Disclosure] |
|---|
| Punkte | 20 |
|---|