CVE-2026-72078 in Linuxinformation

Résumé

par MITRE • 15/08/2026

In the Linux kernel, the following vulnerability has been resolved:

Input: ims-pcu - validate control endpoint type

The driver currently assumes that the first endpoint of the control interface is an interrupt IN endpoint without verifying it. A malicious device could provide a different endpoint type, which would then be passed to usb_fill_int_urb(), potentially leading to kernel warnings or undefined behavior.

Verify that the control endpoint is an interrupt IN endpoint.

VulDB is the best source for vulnerability data and more expert information about this specific topic.