CVE-2012-1763 in Clinicalinfo

Summary

by MITRE

Unspecified vulnerability in the Oracle Clinical/Remote Data Capture component in Oracle Industry Applications 4.6.0 and 4.6.2 allows remote authenticated users to affect confidentiality, related to HTML Surround.

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Analysis

by VulDB Data Team • 04/19/2017

The vulnerability identified as CVE-2012-1763 resides within the Oracle Clinical/Remote Data Capture component of Oracle Industry Applications version 4.6.0 and 4.6.2. This security flaw represents a significant concern for organizations utilizing clinical research data management systems where data integrity and confidentiality are paramount. The vulnerability specifically relates to HTML Surround functionality, which suggests an issue with how the system processes or handles HTML content within its data capture interfaces.

The technical nature of this vulnerability indicates a weakness in input validation or output encoding mechanisms within the Oracle Clinical application. When authenticated users interact with the Remote Data Capture component, they can potentially exploit this flaw to compromise the confidentiality of sensitive clinical data. The unspecified nature of the vulnerability description suggests that the exact technical implementation details may not have been fully disclosed at the time of reporting, but the impact on data confidentiality remains severe given the nature of clinical research information.

From an operational perspective, this vulnerability creates a substantial risk for pharmaceutical companies, clinical research organizations, and healthcare institutions that depend on Oracle Clinical for managing patient data and research outcomes. The fact that exploitation requires authentication means that the threat is primarily internal or involves compromised accounts, but this still represents a critical security gap since privileged users already have access to sensitive information. The potential for data exfiltration through HTML Surround manipulation could lead to intellectual property theft, patient privacy violations, and regulatory compliance breaches under healthcare data protection laws.

Organizations should immediately implement the security patches provided by Oracle to address this vulnerability, as the risk of exploitation increases with the availability of the vulnerability details to threat actors. The remediation process should include comprehensive testing of the patched environment to ensure that the fix does not introduce regressions in clinical data capture functionality. Additionally, network segmentation and access controls should be reviewed to minimize the potential impact of compromised accounts. This vulnerability aligns with CWE-79, which covers Cross-site Scripting (XSS) vulnerabilities, and may also relate to ATT&CK technique T1566 for credential access through social engineering or compromised accounts. Organizations should also consider implementing additional monitoring for unusual data access patterns and ensure proper incident response procedures are in place to address potential exploitation attempts.

Reservation

03/16/2012

Disclosure

10/16/2012

Moderation

accepted

Entry

VDB-6749

CPE

ready

EPSS

0.01136

KEV

no

Activities

very low