CVE-2016-1605 in Sentinelinfo

Summary

by MITRE

Directory traversal vulnerability in the ReportViewServlet servlet in the server in NetIQ Sentinel 7.4.x before 7.4.2 allows remote attackers to read arbitrary files via a PREVIEW value for the fileType field.

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Analysis

by VulDB Data Team • 03/15/2019

The vulnerability identified as CVE-2016-1605 represents a critical directory traversal flaw within the ReportViewServlet component of NetIQ Sentinel version 7.4.x prior to 7.4.2. This issue resides in the server-side processing of file type parameters, specifically within the PREVIEW functionality that handles report generation and preview operations. The vulnerability stems from insufficient input validation and sanitization mechanisms that fail to properly restrict user-supplied data when constructing file paths for report processing. Attackers can exploit this weakness by manipulating the fileType field parameter to include malicious path traversal sequences such as ../ or ..\ that allow them to navigate outside the intended directory boundaries and access arbitrary files on the server filesystem.

The technical implementation of this vulnerability falls under CWE-22, which specifically addresses Improper Limitation of a Pathname to a Restricted Directory, commonly known as directory traversal or path traversal attacks. This flaw operates at the application layer and demonstrates how inadequate input filtering can lead to unauthorized file access. The ReportViewServlet servlet processes user requests without adequate validation of the PREVIEW parameter, allowing malicious actors to construct file paths that bypass normal access controls. When the servlet receives a request with a manipulated fileType value, it directly incorporates this input into file system operations without proper sanitization or path validation, creating an opportunity for attackers to retrieve sensitive files including configuration data, log files, or even system binaries.

The operational impact of this vulnerability extends beyond simple information disclosure, as it provides attackers with the capability to access potentially sensitive data stored on the server. In the context of NetIQ Sentinel, which is designed for security information and event management, this vulnerability could allow attackers to extract critical log data, configuration files containing credentials, or other sensitive operational information that would otherwise be protected within the application's restricted file system access. The attack vector is particularly concerning because it requires no authentication to exploit, making it a remote code execution or information disclosure vulnerability that can be leveraged by any attacker with network access to the vulnerable system. The implications are significant for organizations relying on NetIQ Sentinel for security monitoring, as this vulnerability could expose the very data that the system is designed to protect.

Organizations affected by CVE-2016-1605 should implement immediate mitigations including applying the vendor-provided patch for NetIQ Sentinel 7.4.2, which addresses the directory traversal vulnerability through proper input validation and sanitization of the fileType parameter. Additionally, network segmentation and access controls should be implemented to limit exposure of the vulnerable servlet to untrusted networks. The ATT&CK framework categorizes this vulnerability under T1083 - File and Directory Discovery, as attackers could use this flaw to enumerate file system contents, and T1213 - Data from Information Repositories, when accessing sensitive data stored within the application's file system. Security monitoring should be enhanced to detect unusual patterns in ReportViewServlet requests, particularly those containing directory traversal sequences, as part of a comprehensive defense-in-depth strategy. System administrators should also conduct thorough file system audits to identify any potential unauthorized access that may have occurred through this vulnerability, ensuring that all affected systems are properly patched and monitored for continued security posture maintenance.

Reservation

01/12/2016

Disclosure

07/31/2016

Moderation

accepted

Entry

VDB-90390

CPE

ready

EPSS

0.03811

KEV

no

Activities

very low

Sources

Want to stay up to date on a daily basis?

Enable the mail alert feature now!