CVE-2016-2300 in IntegraXor
Summary
by MITRE
Ecava IntegraXor before 5.0 build 4522 allows remote attackers to bypass authentication and access unspecified web pages via unknown vectors.
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
Analysis
by VulDB Data Team • 10/19/2018
The Ecava IntegraXor vulnerability identified as CVE-2016-2300 represents a critical authentication bypass flaw in the IntegraXor software platform prior to version 5.0 build 4522. This vulnerability resides within the web-based administrative interface of the system, creating a significant security risk that could allow unauthorized remote access to protected web pages and resources. The affected system operates as a data integration and visualization platform commonly used in industrial control systems and monitoring environments where secure access controls are paramount for operational technology infrastructure.
The technical nature of this vulnerability stems from insufficient authentication mechanisms within the web application layer of IntegraXor. Attackers can exploit unknown vectors to circumvent the normal authentication process that should validate user credentials before granting access to restricted web pages. This authentication bypass occurs at the application level where proper session management and access control checks fail to properly validate user permissions. The vulnerability manifests as a weakness in the software's security architecture that allows malicious actors to gain unauthorized access without providing valid credentials, effectively rendering the authentication system ineffective.
The operational impact of this vulnerability extends beyond simple unauthorized access, potentially compromising the entire industrial control environment that relies on IntegraXor for data visualization and monitoring. Remote attackers could access sensitive operational data, manipulate system configurations, or potentially disrupt critical processes within industrial facilities. The unspecified nature of the affected web pages suggests that the vulnerability could provide access to various administrative functions and data sources within the platform. This type of vulnerability directly aligns with CWE-287 which addresses improper authentication issues in software systems, and represents a significant risk to cybersecurity posture in operational technology environments where system integrity and data confidentiality are critical.
Organizations utilizing affected versions of Ecava IntegraXor should immediately implement mitigation strategies including updating to the patched version 5.0 build 4522 or later, implementing network segmentation to limit access to the affected system, and conducting thorough security assessments of their operational technology infrastructure. The vulnerability demonstrates the importance of maintaining current software versions and implementing proper access controls in industrial environments. Security professionals should also consider implementing additional monitoring and logging mechanisms to detect unauthorized access attempts and establish incident response procedures for potential exploitation of authentication bypass vulnerabilities. This vulnerability type falls under the ATT&CK technique T1078 which covers legitimate credentials for unauthorized access, emphasizing the need for robust authentication mechanisms in industrial control systems.