CVE-2026-4642 in Relion Protection Relays REX610
Summary
by MITRE • 11/27/2026
Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615.
This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0.
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
Analysis
by VulDB Data Team • 11/27/2026
The identified vulnerability represents a critical failure in access control mechanisms within the ABB Relion Protection Relay family, encompassing models such as REX610, RE_611, RBX615, REF615 series, RER615, REC615, REX615, and related 615 and 620 series devices, along with the SMU615 Substation Merging Unit. This flaw is classified as an Incorrect Authorization issue, which fundamentally allows unauthorized entities to perform actions or access resources that they should not be permitted to handle based on their assigned privileges. In the context of industrial control systems and power grid infrastructure, these relays serve as essential components for monitoring electrical parameters and executing protective tripping commands. The absence of proper authorization checks means that an attacker who gains network connectivity to any affected device can bypass security boundaries designed to restrict configuration changes or operational overrides. This type of vulnerability is directly aligned with CWE-269, which defines Improper Privilege Management, indicating a systemic failure in the software architecture to enforce least privilege principles during runtime operations.
From a technical perspective, this authorization flaw likely stems from insufficient validation of user credentials or session tokens when processing commands that modify relay settings, alter protection logic, or initiate control actions. Attackers could exploit this by sending crafted requests over common industrial protocols such as IEC 61850, Modbus TCP, or DNP3, depending on the specific communication interface exposed by the device. Because these devices are often deployed in substation environments where network segmentation may be imperfect or compromised through lateral movement from corporate IT networks, the risk of exploitation is significantly elevated. The vulnerability enables an adversary to escalate privileges without needing valid administrative credentials, effectively neutralizing authentication controls that are supposed to protect critical infrastructure assets. This aligns with MITRE ATT&CK for ICS technique T1078.003, which describes Valid Accounts used in industrial environments, as well as T1499, Endpoint Denial of Service, if the exploitation leads to device instability or unintended tripping events that disrupt power delivery.
The operational impact of this vulnerability is severe due to the safety-critical nature of protection relays. An attacker with unauthorized access could manipulate setpoints for overcurrent, differential, or distance protection schemes, potentially leading to nuisance trips during normal operation or failure to trip during actual fault conditions. Such manipulations can cause widespread power outages, damage expensive generation and transmission equipment due to lack of proper isolation, or create safety hazards for personnel working on energized lines. Furthermore, the ability to alter configuration data without detection undermines the integrity of the entire substation automation system. Since these devices often operate in redundant configurations, an attacker might target a secondary unit to cause asymmetrical behavior that is difficult to diagnose using standard monitoring tools. The persistence of this vulnerability across multiple firmware versions and product lines suggests a deep-seated architectural issue rather than a simple coding error, requiring comprehensive remediation strategies beyond simple patching.
Mitigation efforts must prioritize immediate network segmentation and strict access control policies for all devices communicating with the affected Relion series hardware. Organizations should implement firewalls that inspect industrial protocol traffic to block unauthorized command sequences targeting configuration or control functions. Where possible, deployment of mutual authentication mechanisms such as IEC 62351-4 security standards can help ensure that only authorized management stations interact with these relays. ABB has released firmware updates addressing this flaw; therefore, applying the latest available patches is the primary technical remediation step. However, patching alone may not suffice if underlying network architecture allows unrestricted lateral movement to critical assets. Security teams should also enable detailed logging on affected devices and centralize logs in a SIEM system configured to detect anomalous configuration changes or unauthorized access attempts. Regular vulnerability assessments focusing on industrial protocols and continuous monitoring of device integrity are essential components of a defense-in-depth strategy against this class of authorization bypass vulnerabilities.