Siemens Industrial Edge Cloud Device API Endpoint erweiterte Rechte

CVSS Meta Temp ScoreAktueller Exploitpreis (≈)CTI Interest Score
9.7$5k-$25k0.00

Zusammenfassunginfo

Es wurde eine kritische Schwachstelle in Siemens Industrial Edge Cloud Device, Industrial Edge Device Kit, Industrial Edge Own Device, Industrial Edge Virtual Device, SCALANCE LPE9413, SCALANCE LPE9433, SIMATIC Automation Workstation 19", SIMATIC Automation Workstation 24", SIMATIC HMI MTP1000 Unified Comfort Panel, SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1000, Unified Comfort Panel neutral, SIMATIC HMI MTP1200 Comfort Pro for stand, SIMATIC HMI MTP1200 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1200 Comfort Pro for support arm, SIMATIC HMI MTP1200 Comfort Pro neutral design for stand, SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1200 Unified Comfort Panel, SIMATIC HMI MTP1200 Unified Comfort Panel hygienic, SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1200 Unified Comfort Panel neutral design, SIMATIC HMI MTP1500 Comfort Pro for stand, SIMATIC HMI MTP1500 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1500 Comfort Pro for support arm, SIMATIC HMI MTP1500 Comfort Pro neutral design for stand, SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1500 Unified Comfort Panel, SIMATIC HMI MTP1500 Unified Comfort Panel hygienic, SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1500 Unified Comfort Panel neutral design, SIMATIC HMI MTP1900 Comfort Pro for stand, SIMATIC HMI MTP1900 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1900 Comfort Pro for support arm, SIMATIC HMI MTP1900 Comfort Pro neutral design for stand, SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1900 Unified Comfort Panel, SIMATIC HMI MTP1900 Unified Comfort Panel hygienic, SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1900 Unified Comfort Panel neutral design, SIMATIC HMI MTP2200 Comfort Pro for stand, SIMATIC HMI MTP2200 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP2200 Comfort Pro for support arm, SIMATIC HMI MTP2200 Comfort Pro neutral design for stand, SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm and SIMATIC HMI M gefunden. Dabei betrifft es einen unbekannter Codeteil der Komponente API Endpoint. Die Bearbeitung verursacht erweiterte Rechte. Die Identifikation der Schwachstelle wird mit CVE-2025-40805 vorgenommen. Der Angriff kann über das Netzwerk passieren. Es existiert kein Exploit. Ein Upgrade der betroffenen Komponente wird empfohlen.

Detailsinfo

Eine sehr kritische Schwachstelle wurde in Siemens Industrial Edge Cloud Device, Industrial Edge Device Kit, Industrial Edge Own Device, Industrial Edge Virtual Device, SCALANCE LPE9413, SCALANCE LPE9433, SIMATIC Automation Workstation 19", SIMATIC Automation Workstation 24", SIMATIC HMI MTP1000 Unified Comfort Panel, SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1000, Unified Comfort Panel neutral, SIMATIC HMI MTP1200 Comfort Pro for stand, SIMATIC HMI MTP1200 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1200 Comfort Pro for support arm, SIMATIC HMI MTP1200 Comfort Pro neutral design for stand, SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1200 Unified Comfort Panel, SIMATIC HMI MTP1200 Unified Comfort Panel hygienic, SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1200 Unified Comfort Panel neutral design, SIMATIC HMI MTP1500 Comfort Pro for stand, SIMATIC HMI MTP1500 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1500 Comfort Pro for support arm, SIMATIC HMI MTP1500 Comfort Pro neutral design for stand, SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1500 Unified Comfort Panel, SIMATIC HMI MTP1500 Unified Comfort Panel hygienic, SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1500 Unified Comfort Panel neutral design, SIMATIC HMI MTP1900 Comfort Pro for stand, SIMATIC HMI MTP1900 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP1900 Comfort Pro for support arm, SIMATIC HMI MTP1900 Comfort Pro neutral design for stand, SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm, SIMATIC HMI MTP1900 Unified Comfort Panel, SIMATIC HMI MTP1900 Unified Comfort Panel hygienic, SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design, SIMATIC HMI MTP1900 Unified Comfort Panel neutral design, SIMATIC HMI MTP2200 Comfort Pro for stand, SIMATIC HMI MTP2200 Comfort Pro for support arm and extension unit, SIMATIC HMI MTP2200 Comfort Pro for support arm, SIMATIC HMI MTP2200 Comfort Pro neutral design for stand, SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm and extensio, SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm sowie SIMATIC HMI M entdeckt. Dies betrifft ein unbekannter Teil der Komponente API Endpoint. Mit der Manipulation mit einer unbekannten Eingabe kann eine erweiterte Rechte-Schwachstelle ausgenutzt werden. Klassifiziert wurde die Schwachstelle durch CWE als CWE-639. Dies wirkt sich aus auf Vertraulichkeit, Integrität und Verfügbarkeit. CVE fasst zusammen:

Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.

Auf cert-portal.siemens.com kann das Advisory eingesehen werden. Die Identifikation der Schwachstelle findet seit dem 16.04.2025 als CVE-2025-40805 statt. Die Ausnutzbarkeit gilt als leicht. Der Angriff kann über das Netzwerk passieren. Das Ausnutzen erfordert keine spezifische Authentisierung. Nicht vorhanden sind sowohl technische Details als auch ein Exploit zur Schwachstelle. Als Preis für einen Exploit ist zur Zeit ungefähr mit USD $5k-$25k zu rechnen (Preisberechnung vom 14.01.2026).

Ein Upgrade vermag dieses Problem zu beheben.

Unter anderem wird der Fehler auch in der Verwundbarkeitsdatenbank von CERT Bund (WID-SEC-2026-0073) dokumentiert. If you want to get best quality of vulnerability data, you may have to visit VulDB.

Betroffen

  • Siemens Industrial Edge Devices

Produktinfo

Typ

Hersteller

Name

Lizenz

Webseite

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Zuverlässigkeit: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 9.9
VulDB Meta Temp Score: 9.7

VulDB Base Score: 9.8
VulDB Temp Score: 9.4
VulDB Vector: 🔒
VulDB Zuverlässigkeit: 🔍

CNA Base Score: 10.0
CNA Vector (siemens): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VektorKomplexitätAuthentisierungVertraulichkeitIntegritätVerfügbarkeit
freischaltenfreischaltenfreischaltenfreischaltenfreischaltenfreischalten
freischaltenfreischaltenfreischaltenfreischaltenfreischaltenfreischalten
freischaltenfreischaltenfreischaltenfreischaltenfreischaltenfreischalten

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Zuverlässigkeit: 🔍

Exploitinginfo

Klasse: Erweiterte Rechte
CWE: CWE-639 / CWE-285 / CWE-266
CAPEC: 🔒
ATT&CK: 🔒

Physisch: Nein
Lokal: Nein
Remote: Ja

Verfügbarkeit: 🔒
Status: Nicht definiert

EPSS Score: 🔒
EPSS Percentile: 🔒

Preisentwicklung: 🔍
Aktuelle Preisschätzung: 🔒

0-Dayfreischaltenfreischaltenfreischaltenfreischalten
Heutefreischaltenfreischaltenfreischaltenfreischalten

Threat Intelligenceinfo

Interesse: 🔍
Aktive Akteure: 🔍
Aktive APT Gruppen: 🔍

Gegenmassnahmeninfo

Empfehlung: Upgrade
Status: 🔍

0-Day Time: 🔒

Timelineinfo

16.04.2025 CVE zugewiesen
13.01.2026 +272 Tage Advisory veröffentlicht
13.01.2026 +0 Tage VulDB Eintrag erstellt
14.01.2026 +0 Tage VulDB Eintrag letzte Aktualisierung

Quelleninfo

Hersteller: siemens.com

Advisory: ssa-001536
Status: Bestätigt

CVE: CVE-2025-40805 (🔒)
GCVE (CVE): GCVE-0-2025-40805
GCVE (VulDB): GCVE-100-340562
CERT Bund: WID-SEC-2026-0073 - Siemens Industrial Edge Devices: Schwachstelle ermöglicht das Erlangen von Nutzerrechten

Eintraginfo

Erstellt: 13.01.2026 12:19
Aktualisierung: 14.01.2026 00:43
Anpassungen: 13.01.2026 12:19 (76), 14.01.2026 00:43 (7)
Komplett: 🔍
Cache ID: 216::103

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Diskussion

Bisher keine Kommentare. Sprachen: de + en.

Bitte loggen Sie sich ein, um kommentieren zu können.

Do you want to use VulDB in your project?

Use the official API to access entries easily!