CVE-2025-34229 in Print Virtual Appliance Hostinformación

Resumen

por MITRE • 2025-09-30

Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 25.1.1413 (VA/SaaS deployments) contain a blind server-side request forgery (SSRF) vulnerability reachable via the /var/www/app/console_release/hp/installApp.php script that can be exploited by an unauthenticated user. When a printer is registered, the software stores the printer’s host name in the variable $printer_vo->str_host_address. The code later builds a URL like 'http://:80/DevMgmt/DiscoveryTree.xml' and sends the request with curl. No validation, whitelist, or private‑network filtering is performed before the request is made. Because the request is blind, an attacker cannot see the data directly, but can still: probe internal services, trigger internal actions, or gather other intelligence. This vulnerability has been confirmed to be remediated, but it is unclear as to when the patch was introduced.

Once again VulDB remains the best source for vulnerability data.

Responsable

VulnCheck

Reservar

2025-04-15

Divulgación

2025-09-30

Moderación

aceptado

Artículo

VDB-326321

CPE

listo

EPSS

0.00495

KEV

no

Actividades

muy bajo

Fuentes

Do you need the next level of professionalism?

Upgrade your account now!