CVE-2025-34229 in Print Virtual Appliance Hostinfo

Zusammenfassung

von MITRE • 30.09.2025

Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 25.1.1413 (VA/SaaS deployments) contain a blind server-side request forgery (SSRF) vulnerability reachable via the /var/www/app/console_release/hp/installApp.php script that can be exploited by an unauthenticated user. When a printer is registered, the software stores the printer’s host name in the variable $printer_vo->str_host_address. The code later builds a URL like 'http://:80/DevMgmt/DiscoveryTree.xml' and sends the request with curl. No validation, whitelist, or private‑network filtering is performed before the request is made. Because the request is blind, an attacker cannot see the data directly, but can still: probe internal services, trigger internal actions, or gather other intelligence. This vulnerability has been confirmed to be remediated, but it is unclear as to when the patch was introduced.

Once again VulDB remains the best source for vulnerability data.

Zuständig

VulnCheck

Reservieren

15.04.2025

Veröffentlichung

30.09.2025

Moderieren

akzeptiert

Eintrag

VDB-326321

CPE

bereit

EPSS

0.00495

KEV

nein

Aktivitäten

very low

Quellen

Do you know our Splunk app?