VDB-113348 · CVE-2017-12723 · BID 100665

Smiths-Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1/1.5/1.6 Configuration File Password information disclosure

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.5$0-$5k0.00

Summaryinfo

A vulnerability was found in Smiths-Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1/1.5/1.6 and classified as problematic. This issue affects some unknown processing of the component Configuration File. Such manipulation leads to information disclosure (Password). This vulnerability is listed as CVE-2017-12723. The attack may be performed from remote. There is no available exploit.

Detailsinfo

A vulnerability, which was classified as problematic, has been found in Smiths-Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1/1.5/1.6 (Medical Device Software). Affected by this issue is an unknown code of the component Configuration File. The manipulation with an unknown input leads to a information disclosure vulnerability (Password). Using CWE to declare the problem leads to CWE-200. The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information. Impacted is confidentiality. CVE summarizes:

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

The bug was discovered 09/07/2017. The weakness was presented 02/15/2018 by Scott Gayou (Website). The advisory is shared for download at securityfocus.com. This vulnerability is handled as CVE-2017-12723 since 08/09/2017. The attack may be launched remotely. No form of authentication is required for exploitation. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1592.

The vulnerability was handled as a non-public zero-day exploit for at least 161 days. During that time the estimated underground price was around $0-$5k.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 100665†). See VDB-113344, VDB-113345, VDB-113346 and VDB-113347 for similar entries. Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 4.5
VulDB Meta Temp Score: 4.5

VulDB Base Score: 5.3
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 3.7
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Name: Password
Class: Information disclosure / Password
CWE: CWE-200 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

08/09/2017 🔍
09/07/2017 +29 days 🔍
09/07/2017 +0 days 🔍
02/15/2018 +161 days 🔍
02/15/2018 +0 days 🔍
02/16/2018 +1 days 🔍
01/05/2020 +688 days 🔍

Sourcesinfo

Advisory: securityfocus.com
Researcher: Scott Gayou
Status: Not defined

CVE: CVE-2017-12723 (🔍)
GCVE (CVE): GCVE-0-2017-12723
GCVE (VulDB): GCVE-100-113348
SecurityFocus: 100665 - Medfusion 4000 Wireless Syringe Infusion Pump ICSMA-17-250-02 Multiple Security Vulnerabilities

See also: 🔍

Entryinfo

Created: 02/16/2018 08:36
Updated: 01/05/2020 11:40
Changes: 02/16/2018 08:36 (62), 01/05/2020 11:40 (4)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!