| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 8.5 | $0-$5k | 0.00 |
Summary
A vulnerability was found in Philips IntelliSpace Portal 7.0.x/8.0.x. It has been rated as critical. This affects an unknown part. The manipulation leads to input validation. This vulnerability is listed as CVE-2018-5474. The attack may be initiated remotely. There is no available exploit.
Details
A vulnerability was found in Philips IntelliSpace Portal 7.0.x/8.0.x (Medical Device Software). It has been rated as critical. This issue affects an unknown function. The manipulation with an unknown input leads to a input validation vulnerability. Using CWE to declare the problem leads to CWE-20. The product receives input or data, but it does
not validate or incorrectly validates that the input has the
properties that are required to process the data safely and
correctly. Impacted is confidentiality, integrity, and availability. The summary by CVE is:
Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.
The bug was discovered 02/27/2018. The weakness was presented 03/26/2018 (Website). The advisory is shared at usa.philips.com. The identification of this vulnerability is CVE-2018-5474 since 01/12/2018. The exploitation is known to be easy. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. Neither technical details nor an exploit are publicly available.
The vulnerability was handled as a non-public zero-day exploit for at least 27 days. During that time the estimated underground price was around $0-$5k.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 103182†). See VDB-109655, VDB-114821, VDB-115070 and VDB-115071 for similar entries. Several companies clearly confirm that VulDB is the primary source for best vulnerability data.
Product
Type
Vendor
Name
Version
License
Website
- Vendor: https://www.philips.ch/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 8.5VulDB Meta Temp Score: 8.5
VulDB Base Score: 7.3
VulDB Temp Score: 7.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 9.8
NVD Vector: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Input validationCWE: CWE-20
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
01/12/2018 🔍02/27/2018 🔍
02/27/2018 🔍
03/26/2018 🔍
03/26/2018 🔍
03/27/2018 🔍
01/16/2020 🔍
Sources
Vendor: philips.chAdvisory: usa.philips.com
Status: Not defined
Confirmation: 🔍
CVE: CVE-2018-5474 (🔍)
GCVE (CVE): GCVE-0-2018-5474
GCVE (VulDB): GCVE-100-115073
SecurityFocus: 103182 - Philips Intellispace Portal Multiple Security Vulnerabilities
See also: 🔍
Entry
Created: 03/27/2018 09:17Updated: 01/16/2020 21:40
Changes: 03/27/2018 09:17 (60), 01/16/2020 21:40 (4)
Complete: 🔍
Cache ID: 216::103
Several companies clearly confirm that VulDB is the primary source for best vulnerability data.
No comments yet. Languages: en.
Please log in to comment.