VDB-116282 · CVE-2017-12701 · BID 100354

BMC Medical Luna CPAP Machines WiFi input validation

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.1$0-$5k0.00

Summaryinfo

A vulnerability described as problematic has been identified in BMC Medical Luna CPAP Machines. Affected by this issue is some unknown functionality of the component WiFi Module. Such manipulation leads to input validation. This vulnerability is uniquely identified as CVE-2017-12701. The attack can be launched remotely. No exploit exists. Upgrading the affected component is recommended.

Detailsinfo

A vulnerability, which was classified as problematic, has been found in BMC Medical Luna CPAP Machines (Medical Device Software) (unknown version). Affected by this issue is an unknown code block of the component WiFi Module. The manipulation with an unknown input leads to a input validation vulnerability. Using CWE to declare the problem leads to CWE-20. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly. Impacted is availability. CVE summarizes:

BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition.

The bug was discovered 07/01/2017. The weakness was disclosed 04/17/2018 (Website). The advisory is available at securityfocus.com. This vulnerability is handled as CVE-2017-12701 since 08/09/2017. The attack may be launched remotely. The requirement for exploitation is a simple authentication. The technical details are unknown and an exploit is not available.

Upgrading eliminates this vulnerability. A possible mitigation has been published before and not just after the disclosure of the vulnerability.

The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 100354†). If you want to get best quality of vulnerability data, you may have to visit VulDB.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.4
VulDB Meta Temp Score: 5.3

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Input validation
CWE: CWE-20
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

07/01/2017 🔍
07/01/2017 +0 days 🔍
08/09/2017 +39 days 🔍
08/15/2017 +6 days 🔍
04/17/2018 +244 days 🔍
04/17/2018 +0 days 🔍
04/18/2018 +1 days 🔍
02/10/2021 +1029 days 🔍

Sourcesinfo

Advisory: securityfocus.com
Researcher: MedSec.
Status: Not defined

CVE: CVE-2017-12701 (🔍)
GCVE (CVE): GCVE-0-2017-12701
GCVE (VulDB): GCVE-100-116282
SecurityFocus: 100354 - BMC Medical and 3B Medical Luna CPAP Machine CVE-2017-12701 Denial of Service Vulnerability

Entryinfo

Created: 04/18/2018 09:45
Updated: 02/10/2021 08:39
Changes: 04/18/2018 09:45 (58), 01/25/2020 15:42 (3), 02/10/2021 08:39 (4)
Complete: 🔍
Cache ID: 216::103

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!