Schneider Electric 66074 MGE Network Management Card Integrated Web Server Parameter improper authorization

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.2$0-$5k0.00

Summaryinfo

A vulnerability has been found in Schneider Electric 66074 MGE Network Management Card and classified as critical. This vulnerability affects unknown code of the component Integrated Web Server. This manipulation as part of Parameter causes improper authorization. This vulnerability is handled as CVE-2018-7245. The attack can be initiated remotely. There is not any exploit available.

Detailsinfo

A vulnerability has been found in Schneider Electric 66074 MGE Network Management Card (SCADA Software) (the affected version unknown) and classified as critical. Affected by this vulnerability is an unknown part of the component Integrated Web Server. The manipulation as part of a Parameter leads to a improper authorization vulnerability. The CWE definition for the vulnerability is CWE-285. The product does not perform or incorrectly performs an authorization check when an actor attempts to access a resource or perform an action. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:

An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization.

The bug was discovered 03/15/2018. The weakness was released 04/18/2018 (Website). The advisory is shared at schneider-electric.com. This vulnerability is known as CVE-2018-7245 since 02/19/2018. The exploitation appears to be easy. The attack can be launched remotely. The exploitation doesn't need any form of authentication. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1548.002 for this issue.

The vulnerability was handled as a non-public zero-day exploit for at least 34 days. During that time the estimated underground price was around $0-$5k.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Entries connected to this vulnerability are available at VDB-116579, VDB-116580 and VDB-116582. If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.2
VulDB Meta Temp Score: 8.2

VulDB Base Score: 7.3
VulDB Temp Score: 7.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.1
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Improper authorization
CWE: CWE-285 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

02/19/2018 🔍
03/15/2018 +24 days 🔍
04/18/2018 +33 days 🔍
04/18/2018 +0 days 🔍
04/19/2018 +1 days 🔍
01/27/2020 +648 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: schneider-electric.com
Status: Not defined
Confirmation: 🔍

CVE: CVE-2018-7245 (🔍)
GCVE (CVE): GCVE-0-2018-7245
GCVE (VulDB): GCVE-100-116581
See also: 🔍

Entryinfo

Created: 04/19/2018 08:45
Updated: 01/27/2020 19:26
Changes: 04/19/2018 08:45 (58), 01/27/2020 19:26 (2)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to know what is going to be exploited?

We predict KEV entries!