Schneider Electric Pelco Sarix Professional up to 3.29 Request Password access control

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.2$0-$5k0.00

Summaryinfo

A vulnerability, which was classified as problematic, has been found in Schneider Electric Pelco Sarix Professional up to 3.29. The impacted element is an unknown function. Performing a manipulation as part of Request results in access control (Password). This vulnerability was named CVE-2018-7781. The attack may be initiated remotely. There is no available exploit. It is advisable to upgrade the affected component.

Detailsinfo

A vulnerability classified as problematic has been found in Schneider Electric Pelco Sarix Professional up to 3.29 (SCADA Software). This affects an unknown functionality. The manipulation as part of a Request leads to a access control vulnerability (Password). CWE is classifying the issue as CWE-264. This is going to have an impact on confidentiality. The summary by CVE is:

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.

The bug was discovered 04/24/2018. The weakness was presented 07/03/2018 (Website). It is possible to read the advisory at schneider-electric.com. This vulnerability is uniquely identified as CVE-2018-7781 since 03/08/2018. It is possible to initiate the attack remotely. The successful exploitation needs a authentication. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1068 according to MITRE ATT&CK.

The vulnerability was handled as a non-public zero-day exploit for at least 70 days. During that time the estimated underground price was around $0-$5k.

Upgrading to version 3.29.69 eliminates this vulnerability.

See VDB-120302 and VDB-120304 for similar entries. Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.6
VulDB Meta Temp Score: 6.4

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 8.8
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Name: Password
Class: Access control / Password
CWE: CWE-264
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: Pelco Sarix Professional 3.29.69

Timelineinfo

03/08/2018 🔍
04/24/2018 +47 days 🔍
07/03/2018 +69 days 🔍
07/03/2018 +0 days 🔍
07/04/2018 +1 days 🔍
02/25/2020 +601 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: schneider-electric.com
Status: Not defined

CVE: CVE-2018-7781 (🔍)
GCVE (CVE): GCVE-0-2018-7781
GCVE (VulDB): GCVE-100-120303
See also: 🔍

Entryinfo

Created: 07/04/2018 08:48
Updated: 02/25/2020 07:41
Changes: 07/04/2018 08:48 (62), 02/25/2020 07:41 (1)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!