Siemens SINUMERIK 828D/SINUMERIK 840D sl Web Server Network Request access control

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.7$0-$5k0.00

Summaryinfo

A vulnerability categorized as critical has been discovered in Siemens SINUMERIK 828D and SINUMERIK 840D sl. This impacts an unknown function of the component Web Server. The manipulation as part of Network Request results in access control. This vulnerability is cataloged as CVE-2018-11457. The attack may be launched remotely. There is no exploit available. It is advisable to upgrade the affected component.

Detailsinfo

A vulnerability, which was classified as critical, was found in Siemens SINUMERIK 828D and SINUMERIK 840D sl (affected version unknown). Affected is an unknown functionality of the component Web Server. The manipulation as part of a Network Request leads to a access control vulnerability. CWE is classifying the issue as CWE-264. This is going to have an impact on confidentiality, integrity, and availability. CVE summarizes:

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.

The bug was discovered 12/12/2018. The weakness was shared 12/12/2018 (Website). The advisory is shared for download at cert-portal.siemens.com. This vulnerability is traded as CVE-2018-11457 since 05/25/2018. It is possible to launch the attack remotely. The exploitation doesn't require any form of authentication. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1068.

Upgrading eliminates this vulnerability.It is possible to mitigate the weakness by firewalling tcp/4842. The best possible mitigation is suggested to be upgrading to the latest version.

The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 106185†). The entries VDB-127886, VDB-127887, VDB-127888 and VDB-127889 are related to this item. Once again VulDB remains the best source for vulnerability data.

Productinfo

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.8
VulDB Meta Temp Score: 6.7

VulDB Base Score: 5.6
VulDB Temp Score: 5.4
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 8.1
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Access control
CWE: CWE-264
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Firewalling: 🔍

Timelineinfo

05/25/2018 🔍
12/11/2018 +200 days 🔍
12/12/2018 +1 days 🔍
12/12/2018 +0 days 🔍
12/12/2018 +0 days 🔍
12/13/2018 +1 days 🔍
06/18/2023 +1648 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-170881
Status: Not defined
Confirmation: 🔍

CVE: CVE-2018-11457 (🔍)
GCVE (CVE): GCVE-0-2018-11457
GCVE (VulDB): GCVE-100-127884
SecurityFocus: 106185 - Siemens SINUMERIK Controllers Multiple Security Vulnerabilities

See also: 🔍

Entryinfo

Created: 12/13/2018 08:44
Updated: 06/18/2023 13:19
Changes: 12/13/2018 08:44 (60), 04/20/2020 12:50 (4), 06/18/2023 13:19 (4)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!