VDB-130593 · CVE-2018-7815 · BID 106218

Schneider Electric GUIcon 2.0 Eurotherm c3core.dll type confusion

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.5$0-$5k0.00

Summaryinfo

A vulnerability, which was classified as critical, has been found in Schneider Electric GUIcon 2.0. Affected by this issue is some unknown functionality in the library c3core.dll of the component Eurotherm. Performing a manipulation results in type confusion. This vulnerability was named CVE-2018-7815. The attack needs to be approached locally. There is no available exploit.

Detailsinfo

A vulnerability, which was classified as critical, was found in Schneider Electric GUIcon 2.0 (SCADA Software). This affects an unknown functionality in the library c3core.dll of the component Eurotherm. The manipulation with an unknown input leads to a type confusion vulnerability. CWE is classifying the issue as CWE-843. The product allocates or initializes a resource such as a pointer, object, or variable using one type, but it later accesses that resource using a type that is incompatible with the original type. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on c3core.dll which could cause remote code to be executed when parsing a GD1 file

The bug was discovered 12/13/2018. The weakness was presented 02/06/2019 (Website). The advisory is shared at schneider-electric.com. This vulnerability is uniquely identified as CVE-2018-7815 since 03/08/2018. It is possible to initiate the attack remotely. No form of authentication is needed for exploitation. It demands that the victim is doing some kind of user interaction. Technical details are known, but no exploit is available.

The vulnerability was handled as a non-public zero-day exploit for at least 55 days. During that time the estimated underground price was around $0-$5k.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

See VDB-130591 and VDB-130592 for similar entries. Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.5
VulDB Meta Temp Score: 6.5

VulDB Base Score: 5.3
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.8
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Type confusion
CWE: CWE-843
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

03/08/2018 🔍
12/13/2018 +280 days 🔍
02/06/2019 +55 days 🔍
02/07/2019 +1 days 🔍
07/06/2023 +1610 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: schneider-electric.com
Status: Not defined
Confirmation: 🔍

CVE: CVE-2018-7815 (🔍)
GCVE (CVE): GCVE-0-2018-7815
GCVE (VulDB): GCVE-100-130593
SecurityFocus: 106218

See also: 🔍

Entryinfo

Created: 02/07/2019 09:11
Updated: 07/06/2023 14:58
Changes: 02/07/2019 09:11 (58), 05/08/2020 17:42 (2), 07/06/2023 14:58 (3)
Complete: 🔍
Cache ID: 216::103

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.