Medtronic MyCareLink Monitor Conexus Telemetry Protocol cryptographic issue

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.0$0-$5k0.00

Summaryinfo

A vulnerability, which was classified as critical, was found in Medtronic MyCareLink Monitor, CareLink Monitor, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D, Maximo II ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD, Protecta CRT-D and Secura ICD. Impacted is an unknown function of the component Conexus Telemetry Protocol Handler. The manipulation results in cryptographic issue. This vulnerability is identified as CVE-2019-6540. The attack can only be performed from the local network. There is not any exploit available.

Detailsinfo

A vulnerability, which was classified as critical, was found in Medtronic MyCareLink Monitor, CareLink Monitor, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D, Maximo II ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD, Protecta CRT-D and Secura ICD. Affected is some unknown functionality of the component Conexus Telemetry Protocol Handler. The manipulation with an unknown input leads to a cryptographic issue vulnerability. CWE is classifying the issue as CWE-310. This is going to have an impact on confidentiality, integrity, and availability. CVE summarizes:

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

The bug was discovered 03/21/2019. The weakness was released 03/26/2019 (Website). The advisory is shared for download at securityfocus.com. This vulnerability is traded as CVE-2019-6540 since 01/22/2019. The exploitability is told to be difficult. The attack can only be initiated within the local network. The exploitation doesn't require any form of authentication. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1600.

The vulnerability was handled as a non-public zero-day exploit for at least 5 days. During that time the estimated underground price was around $0-$5k.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2019-16099). VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Vendor

Name

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.0
VulDB Meta Temp Score: 6.0

VulDB Base Score: 5.0
VulDB Temp Score: 5.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.5
NVD Vector: 🔍

CNA Base Score: 6.5
CNA Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Cryptographic issue
CWE: CWE-310
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Partially

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/22/2019 🔍
03/21/2019 +58 days 🔍
03/26/2019 +5 days 🔍
03/27/2019 +1 days 🔍
05/22/2025 +2248 days 🔍

Sourcesinfo

Advisory: securityfocus.com
Status: Not defined

CVE: CVE-2019-6540 (🔍)
GCVE (CVE): GCVE-0-2019-6540
GCVE (VulDB): GCVE-100-132456
EUVD: 🔍
SecurityFocus: 107544

Entryinfo

Created: 03/27/2019 06:47
Updated: 05/22/2025 22:47
Changes: 03/27/2019 06:47 (53), 05/21/2020 17:47 (2), 08/08/2023 15:14 (3), 05/22/2025 22:16 (15), 05/22/2025 22:47 (12)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to stay up to date on a daily basis?

Enable the mail alert feature now!