A vulnerability has been found in Siemens CP1604, CP1616, SIAMTIC RF185C, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 and SIMATIC HMI Comfort Panel and classified as problematic. Affected is an unknown function of the component Webserver. The manipulation leads to input validation. This vulnerability is documented as CVE-2019-6568. The attack can be initiated remotely. There is not any exploit available.
Details
A vulnerability was found in Siemens CP1604, CP1616, SIAMTIC RF185C, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 and SIMATIC HMI Comfort Panel (SCADA Software). It has been rated as problematic. This issue affects an unknown part of the component Webserver. The manipulation with an unknown input leads to a input validation vulnerability. Using CWE to declare the problem leads to CWE-20. The product receives input or data, but it does
not validate or incorrectly validates that the input has the
properties that are required to process the data safely and
correctly. Impacted is availability. The summary by CVE is:
A vulnerability has been identified in CP1604 (All versions), CP1616 (All versions), SIAMTIC RF185C (All versions), SIMATIC CP343-1 Advanced (All versions), SIMATIC CP443-1 (All versions), SIMATIC CP443-1 Advanced (All versions), SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 SP Open Controller CPU 1515SP PC (All versions < V2.1.6), SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC RF181-EIP (All versions), SIMATIC RF182C (All versions), SIMATIC RF186C (All versions), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU family (All versions < V3.X.16), SIMATIC S7-400 PN (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-PLCSIM Advanced (All versions), SIMATIC Teleservice Adapter IE Advanced (All versions), SIMATIC Teleservice Adapter IE Basic (All versions), SIMATIC Teleservice Adapter IE Standard (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIMOCODE pro V EIP (All versions), SIMOCODE pro V PN (All versions), SINAMICS G130 V4.6 (All versions), SINAMICS G130 V4.7 (All versions), SINAMICS G130 V4.7 SP1 (All versions), SINAMICS G130 V4.8 (All versions < V4.8 HF6), SINAMICS G130 V5.1 (All versions), SINAMICS G130 V5.1 SP1 (All versions < V5.1 SP1 HF4), SINAMICS G150 V4.6 (All versions), SINAMICS G150 V4.7 (All versions), SINAMICS G150 V4.7 SP1 (All versions), SINAMICS G150 V4.8 (All versions < V4.8 HF6), SINAMICS G150 V5.1 (All versions), SINAMICS G150 V5.1 SP1 (All versions < V5.1 SP1 HF4), SINAMICS S120 V4.6 (All versions), SINAMICS S120 V4.7 (All versions), SINAMICS S120 V4.7 SP1 (All versions), SINAMICS S120 V4.8 (All versions < V4.8 HF6), SINAMICS S120 V5.1 (All versions), SINAMICS S120 V5.1 SP1 (All versions < V5.1 SP1 HF4), SINAMICS S150 V4.6 (All versions), SINAMICS S150 V4.7 (All versions), SINAMICS S150 V4.7 SP1 (All versions), SINAMICS S150 V4.8 (All versions < V4.8 HF6), SINAMICS S150 V5.1 (All versions), SINAMICS S150 V5.1 SP1 (All versions < V5.1 SP1 HF4), SINAMICS S210 V5.1 (All versions), SINAMICS S210 V5.1 SP1 (All versions), SITOP Manager (All versions), SITOP PSU8600 (All versions), SITOP UPS1600 (All versions), TIM 1531 IRC (All versions). The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
The bug was discovered 04/09/2019. The weakness was released 04/17/2019. The identification of this vulnerability is CVE-2019-6568 since 01/22/2019. The exploitation is known to be easy. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. The technical details are unknown and an exploit is not publicly available. The pricing for an exploit might be around USD $5k-$25k at the moment (estimation calculated on 08/29/2023).
The vulnerability was handled as a non-public zero-day exploit for at least 8 days. During that time the estimated underground price was around $5k-$25k.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
Product
Type
Vendor
Name
- CP1604
- CP1616
- SIAMTIC RF185C
- SIMATIC CP343-1 Advanced
- SIMATIC CP443-1
- SIMATIC CP443-1 Advanced
- SIMATIC CP443-1 OPC
- SIMATIC ET 200 SP Open Controller CPU 1515SP PC
- SIMATIC ET 200 SP Open Controller CPU 1515SP PC2
- SIMATIC HMI Comfort Panel
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 6.8VulDB Meta Temp Score: 6.8
VulDB Base Score: 5.3
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 7.5
NVD Vector: 🔍
CNA Base Score: 7.5
CNA Vector (Siemens AG): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Input validationCWE: CWE-20
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
01/22/2019 🔍04/09/2019 🔍
04/17/2019 🔍
04/17/2019 🔍
08/29/2023 🔍
Sources
Vendor: siemens.comAdvisory: ssa-480230
Status: Not defined
CVE: CVE-2019-6568 (🔍)
GCVE (CVE): GCVE-0-2019-6568
GCVE (VulDB): GCVE-100-133451
Entry
Created: 04/17/2019 22:43Updated: 08/29/2023 14:58
Changes: 04/17/2019 22:43 (53), 05/30/2020 09:46 (1), 08/29/2023 14:55 (4), 08/29/2023 14:58 (12)
Complete: 🔍
Cache ID: 216::103
Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.