Siemens Opcenter Execution Discrete unquoted search path

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.3$5k-$25k0.00

Summaryinfo

A vulnerability was found in Siemens Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process, Opcenter Intelligence, Opcenter Quality, Opcenter RD, L, SIMATIC Notifier Server for Windows, SIMATIC PCS neo, SIMATIC STEP 7, SIMOCODE ES and Soft Starter ES. It has been declared as critical. The impacted element is an unknown function. Such manipulation leads to unquoted search path. This vulnerability is documented as CVE-2020-7581. The attack needs to be performed locally. There is not any exploit available.

Detailsinfo

A vulnerability was found in Siemens Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process, Opcenter Intelligence, Opcenter Quality, Opcenter RD, L, SIMATIC Notifier Server for Windows, SIMATIC PCS neo, SIMATIC STEP 7, SIMOCODE ES and Soft Starter ES (SCADA Software). It has been rated as critical. Affected by this issue is some unknown processing. The manipulation with an unknown input leads to a unquoted search path vulnerability. Using CWE to declare the problem leads to CWE-428. The product uses a search path that contains an unquoted element, in which the element contains whitespace or other separators. This can cause the product to access resources in a parent path. Impacted is confidentiality, integrity, and availability. CVE summarizes:

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted.

The weakness was released 07/14/2020 (Website). The advisory is available at cert-portal.siemens.com. This vulnerability is handled as CVE-2020-7581 since 01/21/2020. Local access is required to approach this attack. Required for exploitation is a simple authentication. The technical details are unknown and an exploit is not available. The structure of the vulnerability defines a possible price range of USD $5k-$25k at the moment (estimation calculated on 07/15/2020). This vulnerability is assigned to T1574.009 by the MITRE ATT&CK project.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Entries connected to this vulnerability are available at VDB-158068 and VDB-158069. If you want to get best quality of vulnerability data, you may have to visit VulDB.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.3
VulDB Meta Temp Score: 7.3

VulDB Base Score: 7.8
VulDB Temp Score: 7.8
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.7
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Unquoted search path
CWE: CWE-428 / CWE-426
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: No

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/21/2020 🔍
07/14/2020 +175 days 🔍
07/15/2020 +1 days 🔍
07/15/2020 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: cert-portal.siemens.com
Status: Not defined

CVE: CVE-2020-7581 (🔍)
GCVE (CVE): GCVE-0-2020-7581
GCVE (VulDB): GCVE-100-158066
See also: 🔍

Entryinfo

Created: 07/15/2020 15:29
Updated: 07/15/2020 15:33
Changes: 07/15/2020 15:29 (36), 07/15/2020 15:33 (18)
Complete: 🔍
Cache ID: 216::103

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!