Siemens SICAM WEB firmware for SICAM A8000 RTU prior 05.30 Login Screen Log cross site scripting

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.6$0-$5k0.00

Summaryinfo

A vulnerability marked as problematic has been reported in Siemens SICAM WEB firmware for SICAM A8000 RTU. This issue affects some unknown processing of the component Login Screen. Performing a manipulation results in cross site scripting (Log). This vulnerability was named CVE-2020-15781. The attack may be initiated remotely. There is no available exploit. It is suggested to upgrade the affected component.

Detailsinfo

A vulnerability, which was classified as problematic, was found in Siemens SICAM WEB firmware for SICAM A8000 RTU (Firmware Software). This affects an unknown code of the component Login Screen. The manipulation with an unknown input leads to a cross site scripting vulnerability (Log). CWE is classifying the issue as CWE-79. The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. This is going to have an impact on integrity. The summary by CVE is:

A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.

The weakness was presented 08/14/2020 (Website). The advisory is shared at cert-portal.siemens.com. This vulnerability is uniquely identified as CVE-2020-15781 since 07/15/2020. It is possible to initiate the attack remotely. No form of authentication is needed for exploitation. It demands that the victim is doing some kind of user interaction. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1059.007 for this issue.

Upgrading to version 05.30 eliminates this vulnerability.

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.9
VulDB Meta Temp Score: 6.8

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.6
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Name: Log
Class: Cross site scripting / Log
CWE: CWE-79 / CWE-94 / CWE-74
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SICAM WEB firmware for SICAM A8000 RTU 05.30

Timelineinfo

07/15/2020 🔍
08/14/2020 +30 days 🔍
08/15/2020 +1 days 🔍
08/15/2020 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: cert-portal.siemens.com
Status: Not defined

CVE: CVE-2020-15781 (🔍)
GCVE (CVE): GCVE-0-2020-15781
GCVE (VulDB): GCVE-100-159933

Entryinfo

Created: 08/15/2020 08:27
Updated: 08/15/2020 08:32
Changes: 08/15/2020 08:27 (39), 08/15/2020 08:32 (18)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.