Siemens SIMATIC RTLS Locating Manager up to 2.10.1 default permission

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.5$0-$5k0.00

Summaryinfo

A vulnerability classified as critical has been found in Siemens SIMATIC RTLS Locating Manager up to 2.10.1. The impacted element is an unknown function. The manipulation leads to default permission. This vulnerability is traded as CVE-2020-10050. An attack has to be approached locally. There is no exploit available. It is recommended to upgrade the affected component.

Detailsinfo

A vulnerability was found in Siemens SIMATIC RTLS Locating Manager up to 2.10.1 (SCADA Software) and classified as critical. This issue affects some unknown processing. The manipulation with an unknown input leads to a default permission vulnerability. Using CWE to declare the problem leads to CWE-276. During installation, installed file permissions are set to allow anyone to modify those files. Impacted is confidentiality, integrity, and availability. The summary by CVE is:

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts.

The weakness was shared 09/09/2020 (Website). The advisory is shared at cert-portal.siemens.com. The identification of this vulnerability is CVE-2020-10050 since 03/04/2020. An attack has to be approached locally. Required for exploitation is a simple authentication. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1222 for this issue.

Upgrading to version 2.10.2 eliminates this vulnerability.

The entries VDB-161068 and VDB-161070 are related to this item. If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.8
VulDB Meta Temp Score: 7.6

VulDB Base Score: 7.8
VulDB Temp Score: 7.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.8
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Default permission
CWE: CWE-276 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: No

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SIMATIC RTLS Locating Manager 2.10.2

Timelineinfo

03/04/2020 🔍
09/09/2020 +189 days 🔍
09/10/2020 +1 days 🔍
09/10/2020 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: cert-portal.siemens.com
Status: Not defined

CVE: CVE-2020-10050 (🔍)
GCVE (CVE): GCVE-0-2020-10050
GCVE (VulDB): GCVE-100-161069
See also: 🔍

Entryinfo

Created: 09/10/2020 07:00
Updated: 09/10/2020 07:05
Changes: 09/10/2020 07:00 (40), 09/10/2020 07:05 (18)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!