B. Braun SpaceCom2 prior 012U000062 cleartext transmission

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
3.6$0-$5k0.00

Summaryinfo

A vulnerability has been found in B. Braun SpaceCom2 and classified as problematic. Affected by this issue is some unknown functionality. The manipulation leads to cleartext transmission. This vulnerability is uniquely identified as CVE-2021-33883. The attack is possible to be carried out remotely. No exploit exists. The affected component should be upgraded.

Detailsinfo

A vulnerability was found in B. Braun SpaceCom2. It has been rated as problematic. This issue affects an unknown part. The manipulation with an unknown input leads to a cleartext transmission vulnerability. Using CWE to declare the problem leads to CWE-319. The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. Impacted is confidentiality.

The weakness was disclosed 08/25/2021. The advisory is shared at mcafee.com. The identification of this vulnerability is CVE-2021-33883. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1040 for this issue.

Upgrading to version 012U000062 eliminates this vulnerability.

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Productinfo

Vendor

Name

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 3.7
VulDB Meta Temp Score: 3.6

VulDB Base Score: 3.7
VulDB Temp Score: 3.6
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Cleartext transmission
CWE: CWE-319 / CWE-310
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SpaceCom2 012U000062

Timelineinfo

06/06/2021 🔍
08/25/2021 +80 days 🔍
08/25/2021 +0 days 🔍
08/29/2021 +4 days 🔍

Sourcesinfo

Advisory: mcafee.com
Status: Confirmed

CVE: CVE-2021-33883 (🔍)
GCVE (CVE): GCVE-0-2021-33883
GCVE (VulDB): GCVE-100-181457

Entryinfo

Created: 08/25/2021 17:15
Updated: 08/29/2021 09:11
Changes: 08/25/2021 17:15 (36), 08/29/2021 09:06 (2), 08/29/2021 09:11 (1)
Complete: 🔍
Cache ID: 216::103

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you need the next level of professionalism?

Upgrade your account now!