Schneider Electric NMC2 AOS/NMC3 AOS Web Page Generation cross site scripting
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 3.0 | $0-$5k | 0.00 |
Summary
A vulnerability categorized as problematic has been discovered in Schneider Electric NMC2 AOS and NMC3 AOS. The affected element is an unknown function of the component Web Page Generation Handler. Such manipulation leads to cross site scripting. This vulnerability is listed as CVE-2021-22814. The attack may be performed from remote. There is no available exploit. It is advisable to upgrade the affected component.
Details
A vulnerability, which was classified as problematic, has been found in Schneider Electric NMC2 AOS and NMC3 AOS (SCADA Software) (affected version unknown). Affected by this issue is an unknown functionality of the component Web Page Generation Handler. The manipulation with an unknown input leads to a cross site scripting vulnerability. Using CWE to declare the problem leads to CWE-79. The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. Impacted is integrity.
The weakness was presented 11/17/2021 as icsa-21-313-01. The advisory is available at us-cert.cisa.gov. This vulnerability is handled as CVE-2021-22814. Successful exploitation requires user interaction by the victim. The technical details are unknown and an exploit is not available. This vulnerability is assigned to T1059.007 by the MITRE ATT&CK project.
Upgrading eliminates this vulnerability.
If you want to get best quality of vulnerability data, you may have to visit VulDB.
Product
Type
Vendor
Name
License
Website
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 3.1VulDB Meta Temp Score: 3.0
VulDB Base Score: 3.1
VulDB Temp Score: 3.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Cross site scriptingCWE: CWE-79 / CWE-94 / CWE-74
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Timeline
01/06/2021 🔍11/17/2021 🔍
11/17/2021 🔍
11/19/2021 🔍
Sources
Vendor: schneider-electric.comAdvisory: icsa-21-313-01
Status: Confirmed
CVE: CVE-2021-22814 (🔍)
GCVE (CVE): GCVE-0-2021-22814
GCVE (VulDB): GCVE-100-186698
Entry
Created: 11/17/2021 14:47Updated: 11/19/2021 09:10
Changes: 11/17/2021 14:47 (38), 11/19/2021 09:10 (1)
Complete: 🔍
Cache ID: 216::103
If you want to get best quality of vulnerability data, you may have to visit VulDB.
No comments yet. Languages: en.
Please log in to comment.