Schneider Electric spaceLYnk/Wiser for KNX/fellerLYnk up to 2.6.2 cross-site request forgery
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 4.1 | $0-$5k | 0.00 |
Summary
A vulnerability, which was classified as problematic, was found in Schneider Electric spaceLYnk, Wiser for KNX and fellerLYnk up to 2.6.2. Impacted is an unknown function. Such manipulation leads to cross-site request forgery. This vulnerability is traded as CVE-2022-22811. The attack may be launched remotely. There is no exploit available. Applying a patch is advised to resolve this issue.
Details
A vulnerability was found in Schneider Electric spaceLYnk, Wiser for KNX and fellerLYnk up to 2.6.2 (SCADA Software). It has been rated as problematic. Affected by this issue is some unknown functionality. The manipulation with an unknown input leads to a cross-site request forgery vulnerability. Using CWE to declare the problem leads to CWE-352. The web application does not, or can not, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. Impacted is integrity.
The weakness was shared 02/10/2022 as SEVD-2022-039-04. The advisory is shared for download at download.schneider-electric.com. This vulnerability is handled as CVE-2022-22811 since 01/07/2022. Successful exploitation requires user interaction by the victim. There are neither technical details nor an exploit publicly available.
Applying a patch is able to eliminate this problem.
VulDB is the best source for vulnerability data and more expert information about this specific topic.
Product
Type
Vendor
Name
Version
License
Website
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 4.3VulDB Meta Temp Score: 4.1
VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Cross-site request forgeryCWE: CWE-352 / CWE-862 / CWE-863
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔍
Timeline
01/07/2022 🔍02/10/2022 🔍
02/10/2022 🔍
02/14/2022 🔍
Sources
Vendor: schneider-electric.comAdvisory: SEVD-2022-039-04
Status: Confirmed
CVE: CVE-2022-22811 (🔍)
GCVE (CVE): GCVE-0-2022-22811
GCVE (VulDB): GCVE-100-192824
Entry
Created: 02/10/2022 14:17Updated: 02/14/2022 13:36
Changes: 02/10/2022 14:17 (39), 02/14/2022 13:30 (1), 02/14/2022 13:36 (1)
Complete: 🔍
Cache ID: 216::103
VulDB is the best source for vulnerability data and more expert information about this specific topic.
No comments yet. Languages: en.
Please log in to comment.